A feasibility study of 70 kV double low-dose coronary imaging technique in abdomen-fatty patients using dual-source CT

Author:

Chen Lei,Ge Shang,Chen Yuan,Zhang Ting-Ting,Zhang Ting-Ting,Zhu Zhao-Huan

Abstract

Objective: To investigate the aplication of low contrast agent concentration and low tube voltage in coronary CTA on patientswith high BMI (26kg/m2<BMI≤28kg/m2) and ultra-high BMI (BMI>28kg/m2). Methods: 60 patients with high BMI (26kg/m2<BMI≤28kg/m2) and 60 patients with ultra-high BMI (BMI>28kg/m2) wererandomly divided into two groups: double low group A (n=30, tube voltage = 70 KV), double low group B (n=30, tube voltage= 70 KV), processed by SAFIRE iterative reconstruction with 270 mgI/ml contrast agent. Conventional group a (n=30, tubevoltage = 120 KV), conventional group b (n=30, tube voltage = 120 KV), with filtered back projection (FBP) and 370 mg I/mlcontrast agent. the image excellent index (FOM), the effective radiation dose (ED), mean CT value, signal-to-noise ratio (SNR),and contrast-to-noise ratio(CNR) between corresponding groups were compared. Result: There was no significant difference in subjective scores of coronary artery image quality between the two high BMIsubgroups (P>0.05).The ED of group A (1.103±0.101 mSv) was significantly lower than that of group a (4.663±0.412 mSv)(P<0.001).There was no significant difference in mean CT value, SNR and CNR between the two subgroups (P>0.05).The imageexcellent index (FOM) of group A was higher than that of group a (P<0.05).The total iodine content and iodine injectionrate in group A were lower than those in group a (P<0.001).The difference of subjective scores of coronary artery image qualitybetween the two ultra-high subgroups was significant. The mean CT value, SNR and CNR of group B were lower than those ofgroup b (P<0.05). The images of 14 patients in group B could not meet the diagnosis demand. Conclusion: It is feasible to reduce the tube voltage to 70KV in patients with abdominal BMI with high BMI (26Kg/m2<BMI≤28Kg/m2). For patients with abdominal obesity with ultra-high BMI (BMI>28Kg/m2), under the same conditions, the70KV can not meet the daily diagnosis requirement. Keywords: Radiation dose; tomography; coronary artery; iterative reconstruction; contrast agent; abdominal obesity.

Publisher

African Journals Online (AJOL)

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3