Palpation Versus Ultrasonography for Identifying the Cricothyroid Membrane in Case of a Laterally Deviated Larynx: A Randomized Trial

Author:

Lohse Robin1,Wagner Nanna1,Kristensen Michael Seltz1

Affiliation:

1. From the Department of Anaesthesiology, Centre of Head and Orthopaedics, Copenhagen University Hospital, Copenhagen, Denmark.

Abstract

BACKGROUND: Large neck circumference and displacement of the trachea due to pathology increase the risk of failed identification of the cricothyroid membrane and cricothyroidotomy. We investigated whether ultrasound aids in the successful identification of the cricothyroid membrane in a model of an obese neck with midline deviation of the trachea. METHODS: We developed silicone neck models that were suitable for both palpation and ultrasonography and where the trachea deviated laterally from the midline to either side. After reading a book chapter and participating in a 25-minute lecture and a 15- to 23-minute hands-on demonstration and rehearsal of ultrasonography for identification of the cricothyroid membrane, anesthesiologists and anesthesiology residents randomly performed identification with either ultrasound or palpation on 1 of 2 neck models. RESULTS: We included 57 participants, of whom 29 and 28 were randomized to palpation and ultrasound, respectively. Correct identification of the cricothyroid membrane was achieved by 21 (75.0%) vs 1 (3.5%) of participants in the ultrasound versus palpation groups (risk ratio [RR], 21.8 [95% confidence interval {CI}, 3.1–151.0]). The tracheal midline position in the sagittal plane was identified correctly by 24 (85.7%) vs 16 (55.2%) of participants in the ultrasound versus palpation groups (RR, 1.6 [95% CI, 1.1–2.2]). CONCLUSIONS: Identification of the cricothyroid membrane in a model of an obese neck with midline deviation of the trachea was more often successful with ultrasound compared to palpation. Our study supports the potential use of ultrasound before induction of anesthesia and airway management in this group of patients, and it may even be applied in emergency situations when ultrasound is readily available. Further studies in human subjects should be conducted.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3