Phacoemulsification of cataract in the case of capsular bag damage

Author:

Rozukulov V. U.1,Savranova T. N.1,Yusupov A. F.1

Affiliation:

1. Republican scientific and practical medical center of eye microsurgery

Abstract

Purpose: to analyze the results of complicated cataract phacoemulsification with implantation of various types of intraocular lenses and fixation techniques. Material and methods. 48 patients (51 eyes) with complicated cataracts and weakened ligamentous apparatus of the lens or intraoperative rupture of the posterior lens capsule were divided into two groups: the study group I consisted of 21 patients (23 eyes, aged 71.4 ± 4.5 years) who had cataract phacoemulsification with an implantation of RSP-III IOL which was performed through a 2.4 mm small self-sealing incision using an injector and the control group II consisting of 27 patients (28 eyes, aged 73.6 ± 4.1 years) who had. Cataract phacoemulsification with an anterior chamber IOL implantation using an incision widened to 6.0 mm. Results. By the end of 1-year follow-up period, uncorrected visual acuity was 0.8 ± 0.1 in group 1 and 0.5 ± 0.1 in group II. In 100% of the patients of group 1 the correct position of the IOL was achieved in the early postoperative period (1–3 days) and maintained in the late period (1 year), whereas in group II, two eyes of 28 operated (7.14 %) showed a forward displacement of the anterior chamber IOL, which involved a contact with corneal endothelium. IOP stayed within the normal range in 21 eyes of group I patients (91.3 %), albeit two eyes (8.7 %) revealed transitory hypertension. In group II, 21 eyes (75 %) had normal IOP in the first three postoperative days, while 7 eyes (25 %) revealed an IOP increased to 29–30 mm Hg. In contrast to group I, group II patients showed induced corneal astigmatism which was decreasing during the follow-up period. Conclusion. In the case of a rupture of the posterior capsule during cataract phacoemulsification, or failure of the ligamentous apparatus of the lens of various origins, the implantation of the RSP-III IOL through a small self-sealing incision using an injector is the method of choice, which allows achieving a stable position of the IOL in the early and long-term follow-up periods, and high visual acuity with the minimal values of corneal astigmatism.

Publisher

Real Time, Ltd.

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3