Determination of the error of measurements obtained by the optical micrometry

Author:

Staroverova A. V.1,Tokmachev M. G.2,Gagarin A. N.1,Ferapontov N. B.1

Affiliation:

1. M. V. Lomonosov Moscow State University, Faculty of Chemistry

2. M. V. Lomonosov Moscow State University, Faculty of Physics

Abstract

We present the results of measuring the volume of polyvinyl alcohol polymer granules crosslinked with epichlorohydrin in water and in aqueous solutions of KCl, MgCl2 and their mixtures, obtained by optical micrometry, and consider the main sources of errors in the measurement errors. The purpose of this study is to analyze and evaluate the effect of the main sources of errors on the accuracy of determining the relative volumes of granules, as well as to search for techniques that can minimize the resulting measurement errors. The diameters of the granules were determined using specialized software implementing machine vision algorithms from the images obtained by optical microscopy. Their volumes were calculated using the formula for the volume of the ellipsoid of revolution. The maximum accuracy of volume determination is known to be achieved when the measured granule has a sphere shape. It is shown that deviation from this shape, for example, in case of an ellipsoid, gives errors in determining the third axis of the ellipsoid, invisible in the image, which creates an error in determining the relative volume of the granule. The instrument error is determined and a statistical estimate of the error attributed to the non-sphericity of the granules is given. It is shown that a typical instrument error in determining the relative volumes of granules is 0.4%. The non-sphericity of the measured granules increases the measurement error up to 3.5%. The error for a single granule can be reduced to 2.3% by combination of methodological techniques and statistical processing of the results, whereas and for an ensemble of at least 5 granules — up to 1.5%. The reproducibility of the properties of polymer granules in cyclic measurements was studied. It is shown that the degree of swelling the granules is reproduced with an error of 1%, which allows the sensor to be used repeatedly. The results obtained can be used in experiments and data processing for analytical applications.

Publisher

TEST-ZL Publishing

Subject

Applied Mathematics,Mechanics of Materials,General Materials Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com