A technique for depositing iron, tungsten, molybdenum, and chrome in the determination of selenium and tellurium in alloy steel by ICP-AES method

Author:

Belozerova A. A.1,Mayorova A. V.1,Bardina M. N.1

Affiliation:

1. Institute of Metallurgy of the Ural Branch of the Russian Academy of Sciences; The first President of Russia B. N. Yeltsin Ural Federal University

Abstract

Direct determination of the content of selenium and tellurium impurities in metallurgical materials by the method of inductively coupled plasma atomic emission spectroscopy (ICP-AES) is difficult due to spectral and non-spectral interference from macrocomponents present in the materials under study. The separation of micro-(Se, Te) and macro-components (Fe, W, Mo, Cr, Cu, Ni, Co) through preliminary precipitation is the goal of the study. The use of barium acetate and sodium fluoride as precipitants are shown to provide an effective separation of Se and Te from Fe, W, Mo, and Cr (the content in the analyzed solution is less than 0.1 wt.% of the original) and partial separation from Cu, Ni, and Co (the content in the analyzed solution from 25 to 55 wt.% of the original). Optimal conditions for the deposition of macrocomponents (Fe, W, Mo, Cr) and inhibition of the process of coprecipitation of selenium and tellurium on sediments of macrocomponents for their subsequent ICP-AES determination were determined. The optimal pH for the precipitation of macrocomponents equals 1. The optimal mass of precipitants (barium acetate and sodium fluoride) is 10 and 3 g, respectively. To inhibit the process of coprecipitation of selenium and tellurium on sediments of macrocomponents, it is proposed to use hydrofluoric acid. The optimal volume of hydrofluoric and hydrochloric acids for inhibiting the process of coprecipitation of analytes on sediments of macrocomponents was determined (3 and 6 cm3, respectively). The developed procedure for separating micro-Se, Te from macro-components was tested on standard samples of alloyed steels using the «spike» method. The technique is characterized by satisfactory accuracy and reproducibility, the limit of determination of analytes after separation of macrocomponents is 10–3 wt.%.

Publisher

TEST-ZL Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3