Study on the Effect of Multi-Gap Arrester Truncation on the Overvoltage of Lightning Intrusion Wave

Author:

Huang Weixiang1,Lin Xiuqing2,Chen Qianyi1,Deng Yeqiang3,Wang Yu3,Pan Caiwei3

Affiliation:

1. Guangxi Power Grid Equipment Monitoring and Diagnosis, Engineering Technology Research Center, Electric Power Research Institute of Guangxi Power Grid Co., Ltd., Nanning, Guangxi 530023, P. R. China

2. Measurement Center of Guangxi Power Grid Co., Ltd, Nanning 530025, P. R. China

3. School of Electrical Engineering and Automation, Wuhan University, Wuhan, Hubei 430072, P. R. China

Abstract

Lightning protection near the fan is the key point of lightning protection in wind farm, which affects the safe and effective delivery of wind power resources. At present, the three-phase multi-gap arrester installed on a base tower behind the collector can cooperate with the zinc oxide arrester to reduce the system failure caused by the arrester failure. However, the chopped wave generated by the multi-gap arrester when it acts is transmitted to the fan box transformer along the line, which may threaten the insulation of the transformer winding. Based on the above problems, this paper builds a simulation model on ATP to analyze the impact of wave clipping of multi-gap arrester on the insulation of fan transformer windings, considers the conventional installation mode and the limit installation mode of multi-gap arrester, and calculates that the wave clipping overvoltage generated by multi-gap arrester after being struck by lightning in two cases is the impact on the insulation of fan transformer. Through the simulation analysis, it is found that the higher the amplitude of the lightning current, the larger the amplitude of the overvoltage generated by the truncated wave, the steeper the wave head, and the greater the threat to the insulation of the fan box. The damage degree of round lightning is less than that of counter lightning. When a multi-gap arrester is installed in a collector tower, the 100[Formula: see text]kA lightning current may destroy the insulation of the fan box transformer winding and require additional protective measures. It is recommended that the multi-gap arrester be installed from the next pole tower of the collector tower in the wind farm.

Funder

Research and Development of Lightning Hazard Risk Assessment System for Distribution Lines and Research on Effectiveness of Lightning Protection Technology

Louisville Institute

Publisher

World Scientific Pub Co Pte Ltd

Reference24 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3