NUMERICAL INVESTIGATION OF THE EFFECTS OF BED SHAPE ON THE END-TO-SIDE CABG HEMODYNAMICS

Author:

RAMEZANPOUR MEHDI1ORCID,MAEREFAT MEHDI1,RAMEZANPOUR NAHID2,MOKHTARI-DIZAJI MANIJHE3,ROSHANALI FARIDEH4,NEZAMI FARHAD RIKHTEGAR5ORCID

Affiliation:

1. Department of Mechanical Engineering, Tarbiat Modares University, Tehran, P. O. Box 14115-143, Iran

2. Medical Biotechnology Research Center, Faculty of Paramedicine, Guilan, University of Medical Sciences, Rasht, P. O. Box 41887-94755, Iran

3. Department of Medical Physics, Tarbiat Modares University, Tehran P. O. Box 14115-143, Iran

4. Department of Cardiac Surgery, Day General Hospital, Valiasr Street, Tehran, Iran

5. Institute for Medical Engineering and Science, Massachusetts Institute of Technology, 77 Mass. Ave., Cambridge, Massachusetts, US

Abstract

Disrupted flow initiates and aggravates intimal thickening in the end-to-side (ETS) coronary artery bypass grafting (CABG), which may lead to failure. To enhance the post-intervention hemodynamics, the geometry is either optimized or totally reconfigured. Majority of configurations proposed by researchers have not suited CABG surgery, for they entailed rigorous manipulation on conventional grafts in situ, which was neither swift nor straightforward. The aim of the present study is, thus, to introduce a slight, yet effective, modification to a conventional ETS CABG configuration, and numerically investigate its effects on updated hemodynamic and structural environment, anticipating the longevity of proposed configuration and CABG success. This fairly simple modification may easily be made positioning a pre-designed anastomotic device between the bed of host artery in the conventional ETS CABG and its surrounding tissues. Conducting comprehensive numerical simulations, performance of the proposed configuration was assessed using idealized and patient-specific geometries of the conventional ETS CABG. Blood flow was simulated in a conventional and an updated CABG configuration considering 2-way fluid–structure interaction. Results revealed that, although the proposed configuration may induce higher structural stresses in vessels walls, it may improve important hemodynamic metrics such as wall shear stress gradient, oscillatory shear index, and relative residence time on host artery bed reducing disruption of flow. This study may also set the stage for design engineers and regulatory officials to evolve ETS CABG toward more hemodynamics-friendly approaches. Further in vitro, preclinical, and clinical experiments are, yet, entailed to accomplish ideal designs of procedural guidelines/grafts.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3