Imageless navigation system (Naviswiss) provides accurate component position in total hip arthroplasty with lateral decubitus position for end-stage hip osteoarthritis: A prospective cohort study with CT-validation

Author:

Scholes CoreyORCID,Fatima Manaal,Schwagli Tobias,Liu David

Abstract

AbstractAimsThe Naviswiss system (Naviswiss AG, Brugg, Switzerland) is a handheld imageless navigation device used to improve the accuracy of implant positioning in total hip arthroplasty (THA). However, clinical data for leg length discrepancy and femoral offset is lacking, and the validity of the system has not been reported for patients undergoing THA in the lateral decubitus position. This study aimed to report the accuracy of the device in this patient population.MethodsPatients underwent THA in the lateral decubitus position by a single surgeon. Component positioning measured by the device intraoperatively was compared to postoperative measurements on computed tomography (CT) scans. Agreement between the navigation system and postoperative measurements was reported with respect to acetabular cup inclination, acetabular cup version, femoral offset and leg length discrepancy.ResultsThe mean difference between intraoperative and postoperative CT measurements was within 2° for angular measurements and 2mm for leg length. Absolute differences for the two indices were within 5° and 4mm. Mean bias was 1-2° overestimation for cup orientation and up to 2mm overestimation for leg length change, but 95% limits of agreement did not exceed absolute thresholds of 10° and 10mm, especially after correction for bias. Four cases (12%) were declared intraoperatively for issues with fixation on the greater trochanter. While inclusion of these cases generated acceptable accuracy overall, their omission improved between-case variability in accuracy and reduced the LOA for both offset and leg length.ConclusionsThe accuracy of the Naviswiss system falls within clinically acceptable recommendations for acetabular cup placement, femoral offset and length length. The system could be further improved with regression-based bias correction.

Publisher

Cold Spring Harbor Laboratory

Reference35 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3