Specificity and Performance of Nucleocapsid and Spike-based SARS-CoV-2 Serologic Assays

Author:

Tehrani Zahra RikhtegaranORCID,Saadat SamanORCID,Saleh Ebtehal,Ouyang Xin,Constantine Niel,DeVico Anthony L.,Harris Anthony D,Lewis George K.,Kottilil ShyamORCID,Sajadi Mohammad M.ORCID

Abstract

AbstractThere is an urgent need for an accurate antibody test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this paper, we have developed 3 ELISA methods, trimer spike IgA, trimer spike IgG, and nucleocapsid IgG, for detecting anti-SARS-CoV-2 antibodies. We evaluated their performance in comparison with four commercial ELISAs, EDI™ Novel Coronavirus COVID-19 ELISA IgG and IgM, Euroimmun Anti-SARS-CoV-2 ELISA IgG and IgA, and one lateral flow assay, DPP® COVID-19 IgM/IgG System (Chembio). Both sensitivity and specificity were evaluated and the causes of false-positive reactions were determined.The assays were compared using 300 pre-epidemic samples and 100 PCR-confirmed COVID-19 samples. The sensitivities and specificities of the assays were as follows: 90%/100% (in-house trimer spike IgA), 90%/99.3% (in-house trimer spike IgG), 89%/98.3% (in-house nucleocapsid IgG), 73.7%/100% (EDI nucleocapsid IgM), 84.5%/95.1% (EDI nucleocapsid IgG), 95%/93.7% (Euroimmun S1 IgA), 82.8%/99.7% (Euroimmun S1 IgG), 82.0%/91.7% (Chembio nucleocapsid IgM), 92%/93.3% (Chembio nucleocapsid IgG).The presumed causes of positive signals from pre-epidemic samples in commercial and in-house assays were mixed. In some cases, positivity varied with assay repetition. In other cases, reactivity was abrogated by competitive inhibition (spiking the sample with analyte prior to performing the assay). In other cases, reactivity was consistently detected but not abrogated by analyte spiking.Overall, there was wide variability in assay performance using our samples, with in-house tests exhibiting the highest combined sensitivity and specificity. The causes of “false positivity” in pre-epidemic samples may be due to plasma antibodies apparently reacting with the analyte, or spurious reactivity may be directed against non-specific components in the assay system. Identification of these targets will be essential to improving assay performance.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3