Fine Needle Aspiration Versus the CytoCore® Motorized Rotating Needle Device for Thyroid Nodule Biopsies: A Retrospective Cohort Study

Author:

Verma Adarsh,McDowell Rhonda,Porreca Anthony

Abstract

AbstractBackgroundWhile ultrasound guided fine needle aspiration (US-FNA) is commonly used to biopsy suspicious thyroid nodules, its use is associated with a high rate of nondiagnostic and indeterminate samples. The objective of this study was to compare the diagnostic performance of a new motorized FNA device (CytoCore®, Praxis Medical) to a historical cohort of patients biopsied using US-FNA within the same health system and literature controls.Materials and MethodsData from 120 patients with suspicious thyroid nodules undergoing thyroid biopsy with a motorized FNA device between March 2022 and August 2023 was retrospectively analyzed. Patient demographics, lesion characteristics, number of passes required, Bethesda category, and cellularity scores were compared to a historical control cohort of 100 patients who underwent US-FNA between March 2019 and March 2020. All patients underwent the procedure within the same health system. Nondiagnostic and indeterminate samples rates for the motorized FNA device were separately compared to literature controls.ResultsA significantly reduced median number of passes were required with the motorized FNA device compared to US-FNA (z= 8.235,p< .001). Adequate samples were obtained after the first pass for 58% of nodules biopsied with motorized FNA device compared to only 11% with US-FNA. The cumulative percentage of adequate samples increased to 98% after two passes for the motorized FNA group versus only 58% for the US-FNA group. Eleven percent of subjects in the US-FNA required 5 passes to obtain an adequate sample. The mean cellularity score was also greater for the motorized FNA group (3.5 ± 0.5 vs. 2.0 ± 0.6;z= 5.201,p< .001). Compared to published rates, the motorized had a lower nondiagnostic rate (2.0% vs. 10% to 15%) and lower indeterminate rate (8.3% vs. 20%; p=0.05) compared to the use of FNA.ConclusionThe motorized FNA device requires less passes to obtain an adequate biopsy than US-FNA, thus decreasing procedure length, tissue trauma, and damage to the specimen damage. Its use is also associated with obtaining samples with a higher cellularity and lower nondiagnostic and indeterminate sample rates.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3