Quantifying the impact of UVC in reducing airborne pathogen transmission and improving energy efficiency for healthy buildings: Kahn-Mariita equivalent ventilation model

Author:

Kahn KevinORCID,Mariita Richard M.ORCID

Abstract

AbstractThere is growing evidence that viruses responsible for pandemics, such as MERS and SARS, are mainly spread through aerosols. Recommendations have been introduced to reduce the transmission risk of virulent airborne viral particles by increasing ventilation rates, expressed in air-changes-per-hour (ACH), effectively improving the dilution of airborne pathogens via mechanical ventilation. However, the infrastructural and operational costs associated with upgrades of Heating, Ventilation, and Air Conditioning (HVAC) systems make these solutions expensive. It is well documented that UVC disinfection can help lower exposure risks by inactivating viruses in shared enclosed spaces, and the performances of such solutions be translated into equivalent ventilation (equivalent ACH or eACH). Here, we present the first framework to extract the optimum UVC output requirements for a target eACH, and improve facilities ability to comply with ventilation guidelines at lower energy costs. The Kahn-Mariita (KM) model considers the air quality of a shared enclosed space over time by supplementing existing mechanical ventilation with localized UVC air treatment, whether in recirculating units or upper-air systems, and extracts the systems requirements based on end-user needs by incorporating variables such as room size, occupancy, existing ventilation, and target eACH. An example of a conference room shows that a UVC chamber with an air recirculation rate of 160m3/h increases the ventilation from ACH=3 to eACH=7.9 and reduce down-time from 46 minutes to <10 minutes with as little 1W of UVC output. A recirculation rate of 30m3/h however offers no noticeable benefits above 200mW, with a maximum reachable eACH=3.9 and down-time of approximately 31 minutes. The KM model is unique in that it allows for the first time to find the optimum UVC output needs to ensure air quality is maintained and transmission risk minimized, while increasing energy savings. Recent studies suggest mechanically increasing fresh air supply will more than double the energy costs of HVAC systems, while the use of UVC reduces energy demand as much as by 50%. The KM model approaches air quality and energy efficiency in a unified way by incorporating UVC as a supplement to existing ventilation to increase eACH, reduce down-time, and increase the closed space occupancy.

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3