Stability, survival, patient satisfaction, and cost-minimization of CAD/CAM versus conventional multistranded fixed retainers in orthodontic patients: a 2-year follow-up of a two-centre randomized controlled trial

Author:

Pullisaar Helen1,Cattaneo Paolo M2ORCID,Gera Arwa2ORCID,Sankiewicz Monika2,Bilińska Małgorzata2,Vandevska-Radunovic Vaska1,Cornelis Marie A2ORCID

Affiliation:

1. Department of Orthodontics, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo , Geitmyrsveien 69/71 , Oslo 0455 , Norway

2. Section of Orthodontics, Department of Dentistry and Oral Health, Aarhus University , Vennelyst Boulevard 9, 8000 Aarhus C , Denmark

Abstract

Summary Background CAD/CAM (computer-aided design/computer-aided manufacturing) fixed retainers (FRs) as an alternative to multistranded FRs to maintain orthodontic treatment outcome. Objectives The primary aim was to compare CAD/CAM versus conventional multistranded FRs in terms of stability until 2 years. Secondary outcomes were failure rates, patient satisfaction, and cost-minimization. Trial design 2-arm parallel, two-centre randomized controlled trial. Methods Patients were randomized to CAD/CAM or conventional FRs in both arches, in a 1:1 ratio and blocks of four. Allocation concealment was secured by using sequentially numbered envelopes. Patients were blinded. FRs were bonded at the end of treatment, and patients were recalled after 12 and 24 months. First-time retainer failures were recorded and digital impressions were taken. Arch widths and lengths, as well as Little’s Irregularity Index (LII), were measured. Additionally, patients answered satisfaction questionnaires. Linear mixed models were applied for measurements and patient satisfaction. Survival analyses were estimated with Kaplan–Meier curves, along with Cox-regression modelling. Cost-minimization analysis was undertaken. Results One hundred and eighty-one patients were randomized (98 in Centre 1, and 83 in Centre 2): 90 in CAD/CAM and 91 in conventional group. One hundred and fifty three patients attended T24 follow-up. There were no significant differences in LII and arch dimensions between groups for failure-free patients. Within 24 months, 34% maxillary CAD/CAM FRs and 38% maxillary conventional FRs failed, along with 42% mandibular CAD/CAM FRs and 40% mandibular conventional FRs, with no significant difference in survival between groups (hazard ratios conventional to CAD/CAM: maxillary arch: 1.20 [P = 0.46], mandibular arch: 0.98 [P = 0.94]). There were no significant differences in patient satisfaction between groups. No harms were observed. Cost-minimization analysis showed that CAD/CAM FRs were slightly cheaper than conventional FRs. Conclusions There were no clinically significant differences in LII, arch widths, and lengths between CAD/CAM and conventional FRs after 24 months. There were no differences in failures and patient satisfaction between groups. CAD/CAM FRs were slightly cheaper than conventional FRs. Trial registration ClinicalTrials.gov NCT04389879.

Funder

Aarhus University Forskingsfond

European Orthodontic Society Research Grant

Publisher

Oxford University Press (OUP)

Reference35 articles.

1. The rationale for orthodontic retention: piecing together the jigsaw;Millett,2021

2. Retention procedures for stabilising tooth position after treatment with orthodontic braces;Martin,2023

3. Effects of fixed vs removable orthodontic retainers on stability and periodontal health: 4-year follow-up of a randomized controlled trial;Al-Moghrabi,2018

4. Bonded versus vacuum-formed retainers: a randomized controlled trial. Part 1: stability, retainer survival, and patient satisfaction outcomes after 12 months;Forde,2017

5. Vacuum-formed retainer versus bonded retainer for dental stabilization in the mandible—a randomized controlled trial. Part I: retentive capacity 6 and 18 months after orthodontic treatment;Krämer,2019

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3