Analytical and clinical performance characteristics of Tandem-MP Ostase, a new immunoassay for serum bone alkaline phosphatase

Author:

Broyles Dennis L1,Nielsen Randall G1,Bussett Elizabeth M1,Lu W Douglas1,Mizrahi Isaac A1,Nunnelly Patricia A1,Ngo Tram A1,Noell Julia1,Christenson Robert H23,Kress Barry C1

Affiliation:

1. Beckman Coulter, Inc., San Diego, CA 92196

2. Departments of Pathology, University of Maryland School of Medicine, Baltimore, MD 21201

3. Medical and Research Technology, University of Maryland School of Medicine, Baltimore, MD 21201

Abstract

Abstract The performance characteristics of the Tandem®-MP Ostase® assay, a new microplate immunoassay for bone-specific alkaline phosphatase (bone ALP; EC 3.1.3.1) in human sera, are described. Bone ALP is bound to streptavidin-coated microwells by a single biotinylated anti-bone ALP monoclonal antibody. Antigen is detected by the addition of p-nitrophenyl phosphate. The assay is performed at room temperature in <90 min. Imprecision was 2.3–6.1% with a detection limit of 0.6 μg/L. Method comparison of bone ALP measurements with the Tandem-MP Ostase assay and the mass-based Tandem-R Ostase assay (n = 285) indicated regression statistics of Tandem-MP Ostase = 1.03 Tandem-R Ostase + 0.22 μg/L, Sy‖x = 4.0 μg/L, r = 0.97. Serum bone ALP values in apparently healthy men and in pre- and postmenopausal women were also similar between the two Ostase assay formats. Liver ALP reactivity determined using the slope and heat inactivation methods was similar in both Ostase assays. Liver ALP reactivity ranged from 3 μg/L (heat inactivation) to 6 μg/L (slope method) per 100 U/L of liver ALP activity, whereas bone ALP reactivity was 37 μg/L per 100 U/L of bone ALP activity, indicating a liver ALP relative reactivity of 8.1–16.2%. Similar results were obtained with the Alkphase-B bone ALP immunoassay. The Tandem-MP Ostase bone ALP assay demonstrated increased concentrations of serum bone ALP in conditions where bone metabolism is increased and showed a rapid, temporal decrease in serum bone ALP in Paget disease patients on bisphosphonate therapy. In conclusion, the Tandem-MP Ostase assay for serum bone ALP is a rapid, simple, robust nonisotopic alternative to the Tandem-R Ostase immunoradiometric assay that provides an accurate and sensitive assessment of bone turnover.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3