Radioiodinated Tyrosyl-Ouabain and Measurement of a Circulating Ouabain-like Compound

Author:

Vakkuri Olli1,Arnason Sighvatur S2,Joensuu Päivi3,Jalonen Jorma3,Vuolteenaho Olli1,Leppäluoto Juhani1

Affiliation:

1. Department of Physiology, University of Oulu, PO Box 5000, 90401 Oulu, Finland

2. Department of Physiology, University of Iceland, Vatnsmyrarvegi 16, IS-101 Reykjavik, Iceland

3. Department of Chemistry, University of Oulu, PO Box 333, 90571 Oulu, Finland

Abstract

Abstract Background: Assays for endogenous ouabain, a cardiac glycoside believed to be involved in blood pressure and volume regulation, are characterized by laboratory-specific plasma values that are measured by different assays. Because of this variability, our study focused on the development of a new 125I-labeled ouabain derivative for RIA of high sensitivity. Methods: We generated rabbit antisera against a ouabain-thyroglobulin conjugate. A tyrosylated ouabain derivative for radioiodination was synthesized using periodate and sodium cyanoborohydride reagents. Results: Mass spectrometric analyses showed that the main product of the tyrosylating reaction was tyrosyl-ouabain (molecular mass, 702 Da). This was radioiodinated with Chloramine-T and used as a tracer in a RIA, which gave an assay detection limit of 5 pmol/L (4 ng/L), 2–100 times lower than that in the corresponding 3H-RIAs and 2–20 times lower than ouabain ELISAs, making it possible to measure low plasma concentrations of immunoreactive ouabain. Different amounts of SepPak C18-extracted plasma samples displaced the 125I-labeled tyrosyl-ouabain tracer at the same rate at which authentic ouabain was displaced. Plasma immunoreactive ouabain coeluted with authentic ouabain in two different HPLC conditions. Using the new RIA, we found plasma ouabain concentrations, assayed as immunoreactive equivalents, of 10.0 ± 1.3 pmol/L in healthy women and 12.0 ± 0.9 pmol/L in healthy men (mean ± SE; n = 10), as well as 41.2 ± 9.6 pmol/L in rats. The concentrations were 2–90 times lower than those previously reported using different assay methods. Conclusions: Our ouabain 125I-RIA enables reliable measurements of low endogenous concentrations of a ouabain-like compound for both physiological and clinical purposes.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3