Method for the Determination of Total Homocysteine in Plasma and Urine by Stable Isotope Dilution and Electrospray Tandem Mass Spectrometry

Author:

Magera Mark J1,Lacey Jean M1,Casetta Bruno2,Rinaldo Piero1

Affiliation:

1. Mayo Clinic, Department of Laboratory Medicine and Pathology, Biochemical Genetics Laboratory, 200 First St. SW, Rochester, MN 55905

2. PE Biosystems, European Life Science Center, Langen 63225, Germany

Abstract

Abstract Background: Total homocysteine (tHcy) has emerged as an important independent risk factor for cardiovascular disease. Analytical methods are needed to accommodate the high testing volumes for tHcy and provide rapid turnaround. Methods: We developed liquid chromatography electrospray tandem mass spectrometry (LC-MS/MS) method based on the analysis of 100 μL of either plasma or urine with homocystine-d8 (2 nmol) added as internal standard. After sample reduction and deproteinization, the analysis was performed in the multiple reaction monitoring mode in which tHcy and Hcy-d4 were detected through the transition from the precursor to the product ion (m/z 136 to m/z 90 and m/z 140 to m/z 94, respectively). The retention time of tHcy and Hcy-d4 was 1.5 min in a 2.5-min analysis. Results: Daily calibrations between 2.5 and 60 μmol/L exhibited consistent linearity and reproducibility. At a plasma concentration of 0.8 μmol/L, the signal-to-noise ratio for tHcy was 17:1. The regression equation for the comparison between our previous HPLC method (y) and the LC-MS/MS method (x) was y = 1.097x − 1.377 (r = 0.975; Sy|x =1.595 μmol/L; n = 367), and for comparison between a fluorescence polarization immunoassay (Abbott IMx; y) and LC-MS/MS (x) was y = 1.039x + 0.025 (r = 0.969; Sy|x =1.146 μmol/L; n = 367). Inter- and intraassay CVs were 2.9–5.9% and 3.6–5.3%, respectively, at mean concentrations of 3.9, 22.7, and 52.8 μmol/L. Mean recovery of tHcy was 94.2% (20 μmol/L) and 97.8% (50 μmol/L). Conclusions: The sensitivity and specificity of tandem mass spectrometry are well suited to perform high-volume analysis of tHcy. Reagents are inexpensive and sample preparation of a batch of 40 specimens is completed in less than 1 h and is amenable to automation.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3