True-severe stenosis in paradoxical low-flow low-gradient aortic stenosis: outcomes after transcatheter aortic valve replacement

Author:

Okuno Taishi1ORCID,Corpataux Noé1,Spano Giancarlo1,Gräni Christoph1,Heg Dik2,Brugger Nicolas1,Lanz Jonas1ORCID,Praz Fabien1ORCID,Stortecky Stefan1,Siontis George C M1,Windecker Stephan1ORCID,Pilgrim Thomas1ORCID

Affiliation:

1. Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, CH-3010 Bern, Switzerland

2. CTU Bern, University of Bern, Mittelstrasse 43, 3012 Bern, Switzerland

Abstract

Abstract Aims The ESC/EACTS guidelines propose criteria that determine the likelihood of true-severe aortic stenosis (AS). We aimed to investigate the impact of the guideline-based criteria of the likelihood of true-severe AS in patients with low-flow low-gradient (LFLG) AS with preserved ejection fraction (pEF) on outcomes following transcatheter aortic valve replacement (TAVR). Methods and results In a prospective TAVR registry, LFLG-AS patients with pEF were retrospectively categorized into high (criteria ≥6) and intermediate (criteria <6) likelihood of true-severe AS. Haemodynamic, functional, and clinical outcomes were compared with high-gradient AS patients with pEF. Among 632 eligible patients, 202 fulfilled diagnostic criteria for LFLG-AS. Significant haemodynamic improvement after TAVR was observed in LFLG-AS patients, irrespective of the likelihood. Although >70% of LFLG-AS patients had functional improvement, impaired functional status [New York Heart Association (NYHA III/IV)] persisted more frequently at 1 year in LFLG-AS than in high-gradient AS patients (7.8%), irrespective of the likelihood (high: 17.4%, P = 0.006; intermediate: 21.1%, P < 0.001). All-cause death at 1 year occurred in 6.6% of high-gradient AS patients, 10.9% of LFLG-AS patients with high likelihood [hazard ratio (HR)adj 1.43, 95% confidence interval (CI) 0.68–3.02], and in 7.2% of those with intermediate likelihood (HRadj 0.92, 95% CI 0.39–2.18). Among the criteria, only the absence of aortic valve area ≤0.8 cm2 emerged as an independent predictor of treatment futility, a combined endpoint of all-cause death or NYHA III/IV at 1 year (OR 2.70, 95% CI 1.14–6.25). Conclusion Patients with LFLG-AS with pEF had comparable survival but worse functional status at 1 year than high-gradient AS with pEF, irrespective of the likelihood of true-severe AS. Clinical Trial Registration https://www.clinicaltrials.gov. NCT01368250.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Health Policy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3