Anatomic considerations after commando double valve reconstruction: insights for future valve-in-valve therapies

Author:

Simpson Michael T1ORCID,Kachel Matuesz1,Mirza Farooq1,Shea Nicholas J1,Takeda Koji1,Takayama Hiroo1,George Isaac1ORCID

Affiliation:

1. Division of Cardiac, Thoracic & Vascular Surgery, Department of Surgery, New York-Presbyterian Hospital, Columbia University Medical Center , New York, NY, USA

Abstract

Abstract OBJECTIVES The Commando technique for reconstruction of the aortomitral intervalvular fibrous body is effective to facilitate double valve surgery in cases of endocarditis or infiltrative calcification. The length of patch utilized in reconstruction of the intervalvular fibrous body has an important relationship to the geometry of the mitral valve (MV) and aortic valve (AV) and may impact on potential future valve-in-valve (VIV) therapy. Here we report anatomic measurements after Commando reconstruction in a small group of patients and analyse the impact of reconstruction techniques on transcatheter VIV therapies. METHODS Seven patients from January 2018 to April 2022 who underwent double valve surgery with the Commando technique with postoperative computed tomography (CT) scans were identified. Computed tomographic reconstruction of the AV and MV was performed using 3mensio software and virtual transcatheter valve replacement was performed. Two of these patients who had preoperative imaging was analysed to assess the change in aortomitral geometry resulting from reconstruction. RESULTS Measurements for each patient post-reconstruction are given in the table. Aortomitral length was grossly inversely proportional to aortomitral angle (AMA). AMA and aortomitral curtain (AMC) length were significantly altered post-Commando in 2 analysed patients with pre- and postoperative computed tomography scan. Transcatheter AV and MV replacements were feasible in all patients post-Commando. The AMA was larger and more favorable for mitral VIV in patients in which the AMC was short. CONCLUSIONS AMC length, as determined by location of AV annular sutures, may be an important consideration in surgical decision-making for VIV after the Commando procedure.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司