Tetralogy of Fallot and abnormal coronary artery: use of a prosthetic conduit is outdated

Author:

Pontailler Margaux1,Bernard Chloé1,Gaudin Régis1,Moreau de Bellaing Anne1,Mostefa Kara Mansour2,Haydar Ayman1,Barbanti Claudio1,Bonnet Damien2,Vouhé Pascal1,Raisky Olivier1

Affiliation:

1. Department of Pediatric Cardiac Surgery, Necker Sick Children Hospital-M3C, University Paris Descartes, Paris, France

2. Department of Pediatric Cardiology, Necker Sick Children Hospital-M3C, University Paris Descartes, Paris, France

Abstract

AbstractOBJECTIVESRepair of tetralogy of Fallot (ToF) can be challenging in the presence of an abnormal coronary artery (CA) in 5–12% of cases. The aim of this study was to report our experience with ToF repair without the systematic use of a right ventricle-to-pulmonary artery (RV-PA) conduit.METHODSWe conducted a monocentric retrospective study from 2000 to 2016, including 943 patients with ToF who underwent biventricular repair, of whom 8% (n = 76) presented with an abnormal CA. Mean follow-up time was 50 months (1 month–18 years).RESULTSThe most frequent CA anomaly was the left descending artery arising from the right CA (n = 47, 61.8%). The median age at repair was 7.7 months (1.8 months–16 years). Thirteen patients (17%) required prior palliation, mostly systemic pulmonary shunts for anoxic spells in the neonatal period. Surgical repair allowed us to preserve the annulus in 40 patients (53%) by combining PA trunk plasty, commissurotomy and infundibulotomy under the abnormal CA. If the annulus had to be opened (n = 35, 46%), a transannular patch was inserted after a vertical incision of the PA trunk and extended obliquely on the RV over the anomalous crossing CA (with an infundibulotomy under the abnormal CA). Three patients (4%) required the insertion of an RV-PA conduit (1 valved tube and 2 RV-PA GORE-TEX tubes with annulus conservation). The early mortality rate was 4% (n = 3); none of the deaths was coronary related. Four patients (5%) required reoperation (2 early and 2 late reoperations) for residual pulmonary stenosis, 3 of whom had annulus preservation during the initial repair. The mean RV/left ventricle (LV) pressure ratio and an RV/LV pressure ratio >2/3 were identified as risk factors for right ventricular outflow tract (RVOT) reinterventions (P = 0.0026, P = 0.0085, respectively), RVOT reoperations (P = 0.0002 for both) and reoperation for RVOT residual stenosis (P = 0.0002, P = 0.0014, respectively). Two patients underwent pulmonary valve replacement. Freedom from late reoperation was 100% at 1 year, 97% at 5 years and 84% at 10 and 15 years.CONCLUSIONSRepair of ToF and abnormal CA can be performed without an RV-PA conduit, with an acceptable low reintervention rate. The high early mortality rate in this series remains a concern. If any doubt remains about the surgical relief of the RVOT obstruction, the RV/LV pressure ratio should always be measured in the operating room.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3