A systematic review of the psychometric properties of physical performance tests for sarcopenia in community-dwelling older adults

Author:

Exter Sabien H12,Koenders Niek3,Wees Philip4,Berg Manon G A12

Affiliation:

1. Department of Gastro-enterology and Hepatology , Dietetics and Intestinal Failure, , Nijmegen , the Netherlands

2. Radboud University Medical Center , Dietetics and Intestinal Failure, , Nijmegen , the Netherlands

3. Department of Rehabilitation, Radboud University Medical Center , Nijmegen , the Netherlands

4. IQ Healthcare, Radboud University Medical Center , Nijmegen , the Netherlands

Abstract

Abstract Background This review provides an overview of the psychometric properties of the short physical performance battery (SPPB), timed up and go test (TUG), 4 m gait speed test (4 m GST) and the 400 m walk test (400 m WT) in community-dwelling older adults. Methods A systematic search was conducted in MEDLINE, CINAHL and EMBASE, resulting in the inclusion of 50 studies with data from in total 19,266 participants (mean age 63.2–84.3). Data were extracted and properties were given a sufficient or insufficient overall rating following the COSMIN guideline for systematic reviews of patient-reported outcome measures. Quality of evidence (QoE) was rated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Results The SPPB was evaluated in 12 studies, TUG in 30, 4 m GST in 12 and 400 m WT in 2. Reliability of the SPPB, TUG and 4 m GST was rated sufficient (moderate to good QoE). The measurement error of the SPPB was rated insufficient (low QoE). Criterion validity for the SPPB was insufficient in indicating sarcopenia (moderate QoE), while the TUG was sufficient and insufficient for determining mobility limitations (low QoE) and activities of daily living disability (low QoE), respectively. Construct validity of the SPPB, TUG, 4 m GST and 400 m WT was rated insufficient in many constructs (moderate to high QoE). Responsiveness was rated as insufficient for SPPB (high QoE) and TUG (very low QoE), while 4 m GST was rated as sufficient (high QoE). Conclusion Overall, the psychometric quality of commonly used physical performance tests in community-dwelling older adults was generally rated insufficient, except for reliability. These tests are widely used in daily practice and recommended in guidelines; however, users should be cautious when drawing conclusions such as sarcopenia severity and change in physical performance due to limited psychometric quality of the recommended measurement instruments. There is a need for a disease-specific physical performance test for people with sarcopenia. This research received no specific grant from any funding agency and was registered a priori using the International Prospective Register of Systematic Reviews (PROSPERO) (CRD42022359725).

Funder

FoodforCare Foundation

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3