Clinical impact of Bachmann’s bundle pacing defined by electrocardiographic criteria on atrial arrhythmia outcomes

Author:

Infeld Margaret1ORCID,Nicoli Charles D1,Meagher Sean1,Tompkins Bradley J1,Wayne Shawn1,Irvine Benjamin2,Betageri Omkar3,Habel Nicole1,Till Sean1,Lobel Jennings1,Meyer Markus4,Lustgarten Daniel L1

Affiliation:

1. Department of Medicine, Larner College of Medicine, University of Vermont , 111 Colchester Avenue, Burlington, VT 05401 , USA

2. Department of Medicine, Tulane University , New Orleans, Louisiana

3. Department of Medicine, University of Florida , Gainesville, FL , USA

4. Department of Medicine, Lillehei Heart Institute, University of Minnesota , Minneapolis, MN , USA

Abstract

Abstract Aims Evaluate whether Bachmann’s bundle pacing (BBp) defined by electrocardiographic (ECG) criteria is associated with less atrial fibrillation/tachycardia (AF/AT) compared with anatomically defined right atrial septal pacing (RASp) and right atrial appendage pacing (RAAp). Methods and results This is a retrospective study comparing BBp with non-specific RASp and RAAp on new incidence, burden, and recurrence of AF/AT. We included patients who underwent atrial lead placement between 2006 and 2019 and received > 20% atrial pacing. BBp was defined by paced P-wave morphology and fluoroscopic lead position. Compared with RASp (n = 107) and RAAp (n = 108), AF/AT burden was lower in the BBp (n = 134) group by repeated measures ANOVA (P < 0.001). Over 2-year follow-up, AF/AT burden increased in the RASp (P < 0.01) and RAAp (P < 0.01) groups but did not significantly change in the BBp group (P = 0.91). Atrial arrhythmia burden was lower in the BBp group than the RASp and RAAp groups at 12–15, 18–21, and 24–27 months (P < 0.05) after pacemaker placement. Risk of AF/AT recurrence was lower in BBp than RASp (HR 0.43; P < 0.01) and RAAp patients (HR 0.29, P < 0.01). Risk of de novo AF/AT was also lower in BBp than in RASp (OR 0.12; P < 0.01) and RAAp patients (OR 0.20, P < 0.01). Conclusion Bachmann’s bundle pacing defined using P-wave criteria was associated with decreased atrial arrhythmia burden, recurrence, and de novo incidence compared with right atrial septal pacing and right atrial appendage pacing.

Funder

Heart Rhythm Society Research Fellowship and the Cardiovascular Research Institute of Vermont’s Martin M. LeWinter Young Investigator Award and Early Career Research Award

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3