Local Diagnostic Reference Levels for Pediatric Retrograde Wedge Portography Interventional Procedures Using a Dose Monitoring Software at A Transplantation Institute

Author:

Gerasia R123ORCID,Cannataci C4,Gallo G S12,Tafaro C12,Maruzzelli L1,Cortis K4,Miraglia R1

Affiliation:

1. Radiology Unit, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Via Ernesto Tricomi 5, Palermo 90127, Italy

2. Italian Association of Interventional Radiographers (AITRI), Via S. Gregorio, 53, Milan 20124, Italy

3. Italian Federation of Scientific Radiographers Societies (FASTeR), Via S. Gregorio, 53, Milan 20124, Italy

4. Medical Imaging Department, Mater Dei Hospital, Triq Dun Karm, L-Imsida MSD9032, Malta

Abstract

Abstract The aim of this work was to establish local diagnostic reference levels (DRLs) for retrograde wedge portography (RWP) performed on pediatric patients assessing the usefulness of radiation dose monitoring software in the establishing process. Between September 2016 and April 2020, 66 consecutive RWP were performed at a transplantation institute and were included in our study. Patients were divided in three groups according to age: n = 25 infants, n = 20 middle childhood and n = 21 early adolescence. The third quartile of both Air Kerma at the reference point (Ka,r) and air kerma-area product (PKA) were evaluated to establish local DRLs (lDRLs). In addition, to control high Ka,r levels during procedures, the software notified to operators if Ka,r exceeded the dose ‘alert’ threshold set at 2 Gy. lDRLs were established for all three groups using PKA and Ka,r: infant group: 5.6 Gy.cm 2 and 0.034 Gy; middle childhood: 6.4 Gy.cm2 and 0.018 Gy and early adolescence: 12.8 Gy.cm2 and 0.059 Gy. The dose threshold ‘alert’ was never encountered (alert quota: 0%). The dose monitoring system supports the feasibility of accurate and easier lDRLs’ establishment.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference26 articles.

1. Surgical management of portal hypertension in children;Ville;Semin. Pediatr. Surg.,2012

2. Primary prophylaxis of variceal bleeding in children and the role of MesoRex bypass: summary of the Baveno VI pediatric satellite symposium;Shneider;Hepatology,2016

3. Multimodality imaging of the Meso-Rex bypass;Carollo;Abdom. Radiol.,2019

4. Meso-Rex bypass--a procedure to cure prehepatic portal hypertension: the insight and the inside;Di Francesco;J. Am. Coll. Surg.,2014

5. Patient radiation doses and references levels in interventional radiology;Brambilla;Radiol. Med.,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3