Criteria for Identifying Technically Difficult Cases when Performing Sacroiliac Intraarticular Injections Based on the Grade of Sacroiliac Arthrogram

Author:

Kurosawa Daisuke1,Murakami Eiichi1,Aizawa Toshimi2,Watanabe Takashi3,Yabe Yutaka2

Affiliation:

1. Department of Orthopaedic Surgery/Low Back Pain and Sacroiliac Joint Center, JCHO Sendai Hospital, Sendai, Japan

2. Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai, Japan

3. Department of Hospital Medicine, JCHO Sendai Hospital, Sendai, Japan

Abstract

Abstract Objective An intraarticular sacroiliac joint (SIJ) injection cannot always be performed successfully. Based on the patterns of the sacroiliac arthrogram, we explored possible indicators of technically difficult and technically easy injections into the SIJ including demographic features and anatomical features evident on preprocedural imaging. Design Observational study. Methods We evaluated 76 patients with painful SIJ (total 108 joints) diagnosed by SIJ injections. The sacroiliac arthrogram was graded as follows: Grade (G) 0 = the margin of the joint was partially outlined; G1 = the margin was completely outlined; G2 = intraarticular space was substantially outlined; and G3 = intraarticular space was fully outlined. Two multivariable ordered logistic regression analyses were performed to test the relationships between gender, age, and Grade, as well as between computed tomography (CT) findings and grade. Results In men, the totals by Grade were G0 = 8 (joints); G1 = 33; G2 = 3; and G3 = 0. In women, these were G0 = 4; G1 = 28; G2 = 22; and G3 = 10. The Grade was significantly higher in women and was also higher with age (P < 0.05). Regarding morphological features in CT, minor osteophytes increased the odds in favor of better Grades of arthrogram (odds ratio = 3.50). Substantial vacuum phenomena strongly increased the odds of better arthrograms (20.52). Conclusions Outlining the SIJ cavity fully is significantly more difficult in male patients of any age than in aged female patients. The presence of minor osteophytes and substantial vacuum phenomena on preprocedure CT scans can be reasonably reassuring to the practitioner that they are unlikely to encounter difficulties during injection.

Publisher

Oxford University Press (OUP)

Subject

Anesthesiology and Pain Medicine,Neurology (clinical),General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3