Abstract

Abstract Background Left ventricular outflow tract obstruction (LVOTO) sometimes presents with aortic stenosis (AS). Echocardiography is used to assess the diagnosis and severity of LVOTO or AS. However, LVOTO is one of the conditions that makes AS assessment difficult, and catheter pressure measurement is frequently useful in such cases. Case summary An 84-year-old female patient presented with New York Heart Association functional Class III dyspnoea. Transthoracic echocardiography revealed LVOTO caused by upper septal hypertrophy, mitral valve systolic anterior motion with moderate mitral regurgitation, and a highly calcified aortic valve, which suggested the possibility of severe AS. The continuous Doppler echocardiography revealed a late-systolic peaking dagger-shaped profile with a peak jet velocity of 5.6 m/s. Cardiac catheterization was performed to determine the contribution of AS or LVOTO to her symptoms. Catheter pressures were measured at the ascending aorta (using a coronary catheter) and the LV (using the Navvus RXi system). The initial mean pressure gradient between the apex of the LV, just below the aortic valve and aorta, was measured at 65 and 25 mmHg, respectively. The mean pressure gradient between the apex and the aorta decreased from 65 to 40 mmHg after a 50 mg disopyramide administration. Oral medication therapy effectively stabilized her symptom after catheterization. Discussion To the best of our knowledge, this is the first reported case of assessing the severity of LVOTO and AS using the Navvus RXi system. Catheter pressure measurement using the Navvus RXi system is a useful method of determining the severity of LVOTO and AS.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3