Compatibility of transvenous implantable cardioverter defibrillator and vagus nerve stimulation device: a case report

Author:

Thaitirarot Chokanan1ORCID,Sze Shirley12ORCID,Hodson Tim1ORCID,Pathmanathan Ravi1,Dhutia Harshil1ORCID

Affiliation:

1. Glenfield Hospital, University Hospitals of Leicester , Groby Road, Leicester LE3 9QP , UK

2. Department of Cardiovascular Sciences, University of Leicester , Leicester , UK

Abstract

Abstract Background Vagus nerve stimulation (VNS) is an established therapy for drug-resistant epilepsy and depression. While VNS co-existence with cardiac pacemakers is considered safe, its interaction with implantable cardioverter defibrillators (ICDs) remains poorly understood. The concern revolves around the potential for VNS stimulation to interfere with ICD function, potentially resulting in inappropriate therapy or changes in cardiac pacing. Case summary We present the case of a 50-year-old woman with drug-resistant epilepsy who underwent VNS device implantation and subsequent transvenous ICD placement for primary prevention post-myocardial infarction. These devices were thoughtfully situated contralaterally, with a minimum 10 cm separation. Comprehensive testing and follow-up demonstrated no interactions during device programming or serial assessments. Simultaneous interrogation of both devices with their respective telemetry wands caused chaotic artefacts in all channels on the ICD, likely due to electromagnetic interference. Importantly, this interference did not affect ICD sensing. Discussion The co-existence of VNS and ICD in a patient is an emerging scenario with limited previous reports, yet our findings align with prior cases involving VNS and pacemakers. Emphasizing the need for optimal device separation and meticulous evaluation, particularly at maximum VNS output and ICD sensitivity settings, ensures their safe and feasible co-existence. As the use of VNS alongside cardiac implantable electronic devices becomes more common, a diligent evaluation for potential interactions is imperative. Our case highlights the successful co-existence of VNS and ICD, underscoring the importance of careful monitoring and evaluation to guarantee the safe utilization of these two devices.

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3