Placing an intracardiac echocardiogram (ICE) catheter in the left atrium allows for excellent visualization of the left atrial appendage to guide left atrial (LA) appendage occlusion (LAAO). Nonetheless, it requires a separate septal puncture or a unique set of skills to navigate the ICE through a previously prepared septal puncture, which can be challenging.
Case summary
This report describes a novel method to insert an ICE in the left atrium through a single septal puncture utilizing a snare technique. A 76-year-old male underwent LAAO by ICE guidance. After obtaining a standard atrial septal puncture, we were unable to advance the ICE into the left atrium. Therefore, we used a loop snare to grasp the ICE catheter-tip in the right atrium and direct it into the left atrium via the prepared septal puncture by tracking a pigtail wire that we routinely place as part of the procedure. Afterward, the left atrial appendage was successfully occluded with a Watchman device (Boston Scientific, Galway, Ireland), and the patient was discharged home without complications.
Discussion
The described technique could be a helpful tool for ICE placement to the left atrium in a controlled fashion, especially when challenging anatomy is encountered.