Affiliation:
1. General Mills, Inc., 54 S. Michigan Ave, Buffalo, NY 14203
Abstract
Using gas chromatography (GC), 10 collaborating laboratories measured total, saturated, and monounsaturated fats in 8 blind duplicate pairs of foodstuffs. The method involves a hydrolysis/ether extraction of fat followed by quantitative GC analysis versus an internal standard. Calculations were designed to comply with federal regulations as specified in the Nutrition Labeling and Education Act of 1990. The range of fat contents was about 150%. Collaborators received and analyzed (in triplicate) a pre-collaborative sample of known fat content as a practice sample. After satisfactory results were obtained, participants received the 16-sample set. The repeatability standard deviations (RSDr) for total fat ranged from 2.04 to 10.6%; the reproducibility standard deviations (RSDr) for total fat ranged from 3.74 to 15.8%. The hydrolytic extrac- tion-GC method for determination of fat (total, saturated, and monounsaturated) in foodstuffs has been adopted first action by AOAC INTERNATIONAL.
Publisher
Oxford University Press (OUP)
Subject
Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献