GAMMA SPECTRUM STABILIZATION FOR ENVIRONMENTAL RADIATION MONITORING STATIONS USING NAI(TL) DETECTOR

Author:

Hung Dinh Tien1,Van Hiep Cao1,Khang Pham Dinh2,Hai Nguyen Xuan3,Anh Nguyen Ngoc3,Dinh D A4,Hao T V Nhan5,Pham V6

Affiliation:

1. Military Institute of Chemical and Environmental Engineering, Hoai Duc, Hanoi 100000, Vietnam

2. Hanoi University of Science and Technology, 01 Dai Co Viet, Hanoi 100000, Vietnam

3. Dalat Nuclear Research Institute, 01 Nguyen Tu Luc, Dalat 670000, Vietnam

4. NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ho Chi Minh City 700000, Vietnam

5. Faculty of Physics, University of Education, Hue University, Hue 530000, Vietnam

6. Institute of Research and Development, Duy Tan University, Da Nang 550000, Vietnam

Abstract

Abstract Gamma spectrum measured by an NaI(Tl) detector is known to be unstable with the in situ temperature. In the present work, an advanced method has been applied to stabilize the gamma spectrum measured by the NaI(Tl) detector at environmental radiation monitoring (ERM) stations. The method is based on experimental data obtained under controlled conditions in laboratory. In the temperature range from 4 to 45°C, the relative deviation of the peak positions within the stabilized gamma spectrum is less than 2%. To test this method in a real scenario, it has been integrated into the ERM station at the Military Institute of Chemical and Environmental Engineering in Hanoi, Vietnam. The results show that the proposed method is ready for a real application.

Funder

Nuclear Physics

Military Institute of Chemical and Environmental Engineering Research Project

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Handheld Magnetic-Compliant Gamma-Ray Spectrometer for Environmental Monitoring and Scrap Metal Screening;Sensors;2022-02-12

2. Digital Stabilization Algorithm for the Gamma Spectra of Scintillator Detectors in PGNAA;IEEE Transactions on Nuclear Science;2022

3. Flexible and low-cost FPGA-based multichannel analyzer for handheld measurement devices;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2021-12

4. An Embedded Digital Multi-channel Analyzer for Radiation Detection Based on FPGA;Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering;2021

5. A Confident Configuration for an Environmental Radiation Monitoring System;IEEE Transactions on Nuclear Science;2020-10

同舟云学术