Can we rely on wearable sleep-tracker devices for fatigue management?

Author:

Reifman Jaques1ORCID,Priezjev Nikolai V12,Vital-Lopez Francisco G12ORCID

Affiliation:

1. Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command , Fort Detrick, MD , USA

2. The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc. , Bethesda, MD , USA

Abstract

Abstract Study Objectives Wearable sleep-tracker devices are ubiquitously used to measure sleep; however, the estimated sleep parameters often differ from the gold-standard polysomnography (PSG). It is unclear to what extent we can tolerate these errors within the context of a particular clinical or operational application. Here, we sought to develop a method to quantitatively determine whether a sleep tracker yields acceptable sleep-parameter estimates for assessing alertness impairment. Methods Using literature data, we characterized sleep-measurement errors of 18 unique sleep-tracker devices with respect to PSG. Then, using predictions based on the unified model of performance, we compared the temporal variation of alertness in terms of the psychomotor vigilance test mean response time for simulations with and without added PSG-device sleep-measurement errors, for nominal schedules of 5, 8, or 9 hours of sleep/night or an irregular sleep schedule each night for 30 consecutive days. Finally, we deemed a device error acceptable when the predicted differences were smaller than the within-subject variability of 30 milliseconds. We also established the capability to estimate the extent to which a specific sleep-tracker device meets this acceptance criterion. Results On average, the 18 sleep-tracker devices overestimated sleep duration by 19 (standard deviation = 44) minutes. Using these errors for 30 consecutive days, we found that, regardless of sleep schedule, in nearly 80% of the time the resulting predicted alertness differences were smaller than 30 milliseconds. Conclusions We provide a method to quantitatively determine whether a sleep-tracker device produces sleep measurements that are operationally acceptable for fatigue management.

Funder

U.S. Army Medical Research and Development Command

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Neurology (clinical)

Reference30 articles.

1. Wearable sleep technology in clinical and research settings;de Zambotti;Med Sci Sports Exerc.,2019

2. Prospective validation of 2B-Cool: Integrating wearables and individualized predictive analytics to reduce heat injuries;Laxminarayan;Med Sci Sports Exerc.,2023

3. Direct comparison of two new actigraphs and polysomnography in children and adolescents;Meltzer;Sleep.,2012

4. Validation of Zulu watch against polysomnography and actigraphy for on-wrist sleep-wake determination and sleep-depth estimation;Devine,2020

5. A validation study of a commercial wearable device to automatically detect and estimate sleep;Miller;Biosensors,2021

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3