Comparison of Invasive and Oscillometric Blood Pressure Measurement in Obese and Nonobese Children

Author:

Fundora Michael P1ORCID,Beshish Asaad G1,Rao Nikita1,Berry Christopher M2,Figueroa Janet3,McCracken Courtney3,Maher Kevin O1

Affiliation:

1. Children’s Healthcare of Atlanta, Department of Pediatrics, Division of Cardiology, Emory University School of Medicine, Atlanta, Georgia, USA

2. School of Arts and Sciences, Auburn University, Auburn, Alabama, USA

3. Department of Pediatrics, Emory University School of Medicine, Atlanta, Georgia, USA

Abstract

Abstract BACKGROUND Obesity and hypertension are public health priorities, with obesity considered to be a potential cause of hypertension. Accurate blood pressure (BP) determination is required and often obtained by automated oscillometric cuff devices. We sought to determine the correlation of oscillometric measurement in children, and if obesity was associated with worse correlation between methods than nonobese children. METHODS Retrospective matched case-controlled study of 100 obese (97–99th percentile) and 100 nonobese (25–70th percentile) children after cardiac surgery with simultaneous systolic, diastolic, and mean invasive and oscillometric measurements. Matching was 1:1 for age, sex, race, and Risk Adjustment for Congenital Heart Surgery-1 score. Intraclass correlation coefficients and Bland–Altman plots were used to determine agreement with 0.75 as threshold. RESULTS Median age was 13 years (10–15). Agreement was low for systolic (0.65 and 0.61), diastolic (0.68 and 0.61), and mean measurements (0.73 and 0.69) (obese/nonobese). Bland–Altman plots demonstrated oscillometric BP measurements underestimated systolic hypertension (oscillometric readings lower than intra-arterial). Oscillometric measurements underestimated hypotension (systolic oscillometric measurements were higher than intra-arterial). This occurred in obese and nonobese patients. Correlation of oscillometric measurements was similar for nonobese and obese patients. CONCLUSIONS In this first ever study of simultaneous BP measurement by oscillometric vs. intra-arterial in obese and nonobese children, correlation is below accepted norms. The correlation of oscillometric cuff measurements is not affected by habitus in children. There is less correlation between oscillometric measurements and intra-arterial measurements during hypertension or hypotension. Healthcare providers should be aware of the limitations of oscillometric measurements.

Publisher

Oxford University Press (OUP)

Subject

Internal Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Advances in Cuffless Continuous Blood Pressure Monitoring Technology Based on PPG Signals;BioMed Research International;2022-10-01

2. From the Editor-in-Chief: Issue at a Glance;American Journal of Hypertension;2021-06-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3