Breast Cancer Screening With Automated Breast US and Mammography vs Handheld US and Mammography in Women With Dense Breasts in a Real-World Clinical Setting

Author:

Winkelman Andrew J1,Tulenko Kassandra2,Epstein Samantha H3,Nguyen Jonathan V3,Ford Clay4,Miller Matthew M3ORCID

Affiliation:

1. Department of Radiology, University of Michigan Health System , Ann Arbor, MI , USA

2. University of Virginia School of Medicine , Charlottesville, VA , USA

3. Department of Radiology and Medical Imaging, University of Virginia Health System , Charlottesville, VA , USA

4. Senior Research Data Scientist/Statistics, University of Virginia Health System , Charlottesville, VA , USA

Abstract

Abstract Objective We compared the performance of 2 breast cancer screening approaches, automated breast US (ABUS) with same-day mammography (ABUS/MG) and handheld US (HHUS) with same-day mammography (HHUS/MG), in women with dense breasts to better understand the relative usefulness of ABUS and HHUS in a real-world clinical setting. Methods In this institutional review board–approved, retrospective observational study, we evaluated all ABUS/MG and HHUS/MG screening examinations performed at our institution from May 2013 to September 2021. BI-RADS categories, biopsy pathology results, and diagnostic test characteristics (eg, sensitivity, specificity) were compared between the 2 screening approaches using Fisher’s exact test. Results A total of 1120 women with dense breasts were included in this study, with 852 undergoing ABUS/MG and 268 undergoing HHUS/MG. The sensitivities of ABUS/MG and HHUS/MG were 100% (5/5) and 75.0% (3/4), respectively, which was not a statistically significant difference (P  = .444). The ABUS/MG approach demonstrated a slightly higher specificity (97.4% [825/847] vs 94.3% [249/264]; P = .028), higher accuracy (97.4% [830/852] vs 94.0% [252/268]; P = .011), and lower biopsy recommendation rate (3.2% [27/852] vs 6.7% [18/268]; P = .019) than the HHUS/MG approach in our patient population. Conclusion Our findings suggest that ABUS/MG performs comparably with HHUS/MG as a breast cancer screening approach in women with dense breasts in a real-world clinical setting, with the ABUS/MG approach demonstrating a similar sensitivity and slightly higher specificity than the HHUS/MG approach. Additional variables, such as patient experience and physician time, may help determine which imaging approach to employ in specific clinical settings.

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3