Optimized Delta Check Rules for Detecting Misidentified Specimens in Children

Author:

Tan Rui Zhen1,Markus Corey2ORCID,Choy Kay Weng3,Doery James C G34,Loh Tze Ping5

Affiliation:

1. Engineering Cluster, Singapore Institute of Technology, Singapore

2. Metabolic Laboratory, Genetics and Molecular Pathology Directorate, SA Pathology, Women’s and Children’s Hospital, South Australia, Australia

3. Monash Medical Centre, Monash Health, Clayton, Australia

4. Department of Medicine, Monash University, Clayton, Australia

5. Department of Laboratory Medicine, National University Hospital, Singapore

Abstract

Abstract Objectives Preanalytical processes in pediatric patients are generally manual and associated with a higher risk of error. The optimized delta check rules for detecting misidentified children samples are examined. Methods Relative difference and absolute different delta check limits were applied on original and reshuffled (to simulate sample mislabeling/mix-up) paired deidentified pediatric results of 57 laboratory tests. The sensitivity, specificity, and accuracy of a range of delta check limits were determined. The delta check limit associated with the highest accuracy was considered optimal. Results In general, the delta check limits had poor to moderate accuracy (0.50-0.81) in detecting misidentified patient samples. The sensitivity (rule out misidentified sample) quickly deteriorated at increasing delta check limits. At the same time, the specificity (rule in misidentified sample) of the delta check limit was also low. The performance of the relative difference and absolute difference delta check rules was similar. Conclusions Our findings showed poor delta check performance in the pediatric population. The high false-positive flag rate may lead to wasteful resource-intensive investigations and delay in result reporting. In addition, we observed that the optimized pediatric delta check correlated strongly with within-subject biologic variation, whereas delta check accuracy correlated poorly with index of individuality.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Reference19 articles.

1. Blood bank safety practices: mislabeled samples and wrong blood in tube—a Q-Probes analysis of 122 clinical laboratories;Grimm;Arch Pathol Lab Med.,2010

2. How useful are delta checks in the 21st century? A stochastic-dynamic model of specimen mix-up and detection;Ovens;J Pathol Inform.,2012

3. A clinical evaluation of various delta check methods;Wheeler;Clin Chem.,1981

4. CUMS and delta checks: a systematic approach to quality control;Nosanchuk;Am J Clin Pathol.,1974

5. Patient data algorithms;Straseski;Clin Lab Med.,2013

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3