Automation of soil flux chamber measurements: potentials and pitfalls

Author:

Görres Carolyn-Monika,Kammann Claudia,Ceulemans Reinhart

Abstract

Abstract. Recent technological advances have enabled the wider application of automated chambers for soil greenhouse gas (GHG) flux measurements, several of them commercially available. However, few studies addressed the challenges associated with operating these systems. In this contribution we compared two commercial soil GHG chamber systems – the LI-8100A Automated Soil CO2 Flux System and the greenhouse gas monitoring system AGPS. From April until August 2014, the two systems monitored in parallel soil respiration (SR) fluxes at a recently harvested poplar (Populus) plantation, which provided a bare field situation directly after the harvest as well as a closed canopy later on. For the bare field situation (15 April–30 June 2014), the cumulated average SR obtained from the unfiltered data sets of the LI-8100A and the AGPS were 520 and 433 g CO2 m−2 respectively. For the closed canopy phase (1 July–31 August 2014), which was characterized by a higher soil moisture content, the cumulated average SR estimates were not significantly different with 507 and 501 g CO2 m−2 for the AGPS and the LI-8100A respectively. Flux quality control and filtering did not significantly alter the results obtained by the LI-8100A, whereas the AGPS SR estimates were reduced by at least 20 %. The main reasons for the observed differences in the performance of the two systems were (i) a lower data coverage provided by the AGPS due to technical problems; (ii) incomplete headspace mixing in the AGPS chambers; (iii) lateral soil CO2 diffusion below the collars during AGPS chamber measurements; and (iv) a possible overestimation of nighttime SR fluxes by the LI-8100A. Additionally, increased root growth was observed within the LI-8100A collars but not within the AGPS collars, which might have also contributed to the observed differences. In contrast to the LI-8100A, the AGPS had the gas sample inlets installed inside the collars and not the chambers. This unique design feature enabled for the first time the detection of disturbed chamber measurements during nights with a stratified atmosphere, resulting in unbiased nighttime SR estimates. Thus besides providing high temporal frequency flux data, automated chamber systems offer another possibility to greatly improve our understanding of SR fluxes.

Funder

European Research Council

Publisher

Copernicus GmbH

Subject

Earth-Surface Processes,Ecology, Evolution, Behavior and Systematics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3