Field inter-comparison of eleven atmospheric ammonia measurement techniques
-
Published:2010-01-27
Issue:1
Volume:3
Page:91-112
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
von Bobrutzki K.,Braban C. F.,Famulari D.,Jones S. K.,Blackall T.,Smith T. E. L.,Blom M.,Coe H.,Gallagher M.,Ghalaieny M.,McGillen M. R.,Percival C. J.,Whitehead J. D.,Ellis R.,Murphy J.,Mohacsi A.,Pogany A.,Junninen H.,Rantanen S.,Sutton M. A.,Nemitz E.
Abstract
Abstract. Eleven instruments for the measurement of ambient concentrations of atmospheric ammonia gas (NH3), based on eight different measurement methods were inter-compared above an intensively managed agricultural field in late summer 2008 in Southern Scotland. To test the instruments over a wide range of concentrations, the field was fertilised with urea midway through the experiment, leading to an increase in the average concentration from 10 to 100 ppbv. The instruments deployed included three wet-chemistry systems, one with offline analysis (annular rotating batch denuder, RBD) and two with online-analysis (Annular Denuder sampling with online Analysis, AMANDA; AiRRmonia), two Quantum Cascade Laser Absorption Spectrometers (a large-cell dual system; DUAL-QCLAS, and a compact system; c-QCLAS), two photo-acoustic spectrometers (WaSul-Flux; Nitrolux-100), a Cavity Ring Down Spectrosmeter (CRDS), a Chemical Ionisation Mass Spectrometer (CIMS), an ion mobility spectrometer (IMS) and an Open-Path Fourier Transform Infra-Red (OP-FTIR) Spectrometer. The instruments were compared with each other and with the average concentration of all instruments. An overall good agreement of hourly average concentrations between the instruments (R2>0.84), was observed for NH3 concentrations at the field of up to 120 ppbv with the slopes against the average ranging from 0.67 (DUAL-QCLAS) to 1.13 (AiRRmonia) with intercepts of −0.74 ppbv (RBD) to +2.69 ppbv (CIMS). More variability was found for performance for lower concentrations (<10 ppbv). Here the main factors affecting measurement precision are (a) the inlet design, (b) the state of inlet filters (where applicable), and (c) the quality of gas-phase standards (where applicable). By reference to the fast (1 Hz) instruments deployed during the study, it was possible to characterize the response times of the slower instruments.
Publisher
Copernicus GmbH
Subject
Atmospheric Science
Reference71 articles.
1. Asman, W. A. H., Sutton, M. A., and Schjorring, J. K.: Ammonia: emission, atmospheric transport and deposition, New Phytol., 139, 27–48, 1998. 2. Bacon, T., Webber, K., and Carpio, R. A.: Contamination monitoring for ammonia, amines, and acid gases utilizing ion mobility spectroscopy (IMS), Proc. SPIE-Int. Soc. Opt. Eng., Metrology, Inspection and Process Control for Microlithography XII, ISBN 0-8194-2777-2, 3332, 550–559, 1998. 3. Berden, G., Peeters, R., and Meijer, G.: Cavity ring-down spectroscopy: Experimental schemes and applications, Int. Rev. Phys. Chem., 19, 565–607, 2000. 4. Blatter, A., Neftel, A., Dasgupta, P. K., and Simon, P. K.: A combined wet effluent denuder and mist chamber system for deposition measurements of NH3, NH4, HNO3- and NO3, in: Physicochemical Behaviour of Atmospheric Pollutants, edited by: Angeletti, G. and Restelli, G., European Commission, Brussels, 767–772, 1994. 5. Breitenbach, L. P. and Shelef, M.: Development of a method for the analysis of NO2 and NH3 by NO- measuring instruments, J. Air Pollut. Control Assoc., 23, 128–131, 1973.
Cited by
213 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|