Modified Surface Coatings and their Effect on Drug Adsorption within the Extracorporeal Life Support Circuit

Author:

Preston Thomas J.,Ratliff Todd M.,Gomez Daniel,Olshove Vincent F.,Nicol Kathleen K.,Sargel Cheryl L.,Chicoine Louis G.

Abstract

A recently completed study quantified the percent of fentanyl or morphine sulfate lost to uncoated polyvinylchloride (PVC) tubing or to one of two hollow fiber oxygenators within the extracorporeal life support (ECLS) circuit. The results demonstrated the majority of drug loss was due to adsorption by the PVC tubing. The purpose of this study was to determine if a tubing coating process affects fentanyl or morphine Sulfate adsorption. The goal was to quantify fentanyl or morphine sulfate lost due to adhesion within surface modified tubing. The following surface modifications were studied: 1) Maquet Safeline® (synthetic immobilized albumin); 2) Maquet Softline® (a heparin free biopassive polymer); 3) Maquet Bioline® (recombinant human albumin + heparin) (Maquet Cardiopulmonary AG, Hirrlingen, Germany); 4) Terumo X Coating™ (poly2methoxylacrylate)) (Terumo Cardiovascular Systems Corporation, Ann Arbor, MI); 5) Medtronic Carmeda® (covalently bonded heparin); and 6) Medtronic Trillium® (covalently bonded heparin) (Medtronic, Minneapolis, MN). A total of 36 individual circuits were built from the above six available modified surface coatings, for a total of six individual circuits of each coating type. Blood samples were drawn at 5 minutes, 120 minutes, and 360 minutes followed by High-Performance Liquid Chromatography to determine available circulating levels of either fentanyl or morphine sulfate. Fentanyl concentrations decreased to an average final available concentration of 35% (±5%) within the 18 circuits. Morphine sulfate however, decreased to a final available concentration of 57% (±1%) in all Maquet tubing and the Medtronic Trillium tubing, while it decreased to a final concentration of 35% (±1%) in the Medtronic Carmeda coated tubing and in the Terumo X Coating tubing. Biocompatible ECLS circuit surface coatings affected drug-adsorption and availability. Further evaluation is necessary to understand the adsorptive loss of other drugs administered to our patients while on modified surface coated ECLS circuits.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3