Affiliation:
1. Beijing China Coal Mine Engineering Co.,LTD
2. Anhui University of Science and Technology
Abstract
Through the large number uniaxial strength tests and the creep test tests of the artificially frozen soil of Cretaceous strata, we obtained that the frozen wall in Cretaceous strata met the Moore - Coulomb strength criterion, and the artificially frozen soil strength increased from 6.5MPa in -5 °C to 12.0MPa in -15 °Cwith the freezing temperature decreased, Poisson's ratio from 0.35 down to -5 °C -15 °C at 0.18. Using viscoelastic-plastic theory we got the deep frozen wall strength and thickness of the Bojiang - Haizi mine in Cretaceous strata, practice showed that: the design approach in this paper was reasonable.
Publisher
Trans Tech Publications, Ltd.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献