Affiliation:
1. University Politehnica of Bucharest
2. “Gheorghe Asachi” Technical University of Iasi
3. Technical University of Cluj-Napoca
4. Colentina Clinical Hospital
Abstract
The overwhelming majority of medical instrumentation are executed form metalic materials, form the category of austenitic steinlees steel and titan alloys, which poses a good rezistance to corrosion, appropriate mechanical properties, and a good biocompatibility. The lifetime for the medical instrumentation is generaly low due to the modification of surface properties of metal tools from poor maintenance by medical personnel performing decontamination and sterilization operations (having no knowledge of material science), or the the improper use of chemical reagents or low quality of water used in decontamination processes. Identified solutions to improve surface properties of these parts of surgical instruments made of metallic consist of deposition of protective coatings. In this experimental study, we perform different coatings on a substrate made by stainless steel type 316L. We use different coating materials, each deposited by a specific method: hard ceramic biomaterials (TiO2 and YSZ - yttria stabilized zirconia) deposited by the method of deposition and plasma, respectively zirconium carbonitride (mono and multilayer) deposited by cathodic arc deposition method.
The obtained coatings was analyzed using scanning electron microscopy coupled with EDS in order to characterize the morphology and composition of the coatings. The selected samples were tested for corrosion resistance. Corrosion resistance was determined by linear polarization technique, which involves plotting the potentiodynamic polarization curves of-1 V (vs. OC) to 1 V (vs SCE), with a scan rate of 0.5 mV / s. The corrosion tests was performed in physiological saline infusion (NaCl concentration 7%) at room temperature (25 ± 1 ° C) according to ASTM G15-97a. As a general conclusion we can say that layers ZrCN based presents the best parameter values of corrosion and therefore the best corrosion resistance in the case of surgical instruments.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,General Materials Science
Reference7 articles.
1. S. Sathish, M. Geetha, N.D. Pandey, C. Richard, R. Asokamani, Studies on the corrosion and wear behavior of the laser nitrided biomedical titanium and its alloys, Mater. Sci. Eng. C 30 (2010) 376–382.
2. M. Gell, E.H. Jordan, Y.H. Sohn, D. Goberman, L. Shaw, T.D. Xiao, Development and implementation of plasma sprayed nanostructured ceramic coatings, Surf. Coat. Technol. 146–147 (2001) 48–54.
3. M.F. Morks, A. Kobayashi, Development of ZrO2/SiO2 bioinert ceramic coatings for biomedical application, J. Mech. Behav. Biomed. Mater. 1 (2008) 165–171.
4. M. Balaceanu, M. Braic, V. Braic, G. Pavelescu: Properties of arc plasma deposited TiCN/ZrCN superlattice coatings, Surface & Coatings Technology 200 (2005), p.1084– 1087.
5. C. Munteanu, D.L. Chicet, I.L. Bistricianu, G.L. Pintilei, Innovative character of plasma spray deposition, Acta Technica Napocensis - Series: Applied Mathematics And Mechanics, 54, 2011, 384.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献