Abstract

The overwhelming majority of medical instrumentation are executed form metalic materials, form the category of austenitic steinlees steel and titan alloys, which poses a good rezistance to corrosion, appropriate mechanical properties, and a good biocompatibility. The lifetime for the medical instrumentation is generaly low due to the modification of surface properties of metal tools from poor maintenance by medical personnel performing decontamination and sterilization operations (having no knowledge of material science), or the the improper use of chemical reagents or low quality of water used in decontamination processes. Identified solutions to improve surface properties of these parts of surgical instruments made ​​of metallic consist of deposition of protective coatings. In this experimental study, we perform different coatings on a substrate made by stainless steel type 316L. We use different coating materials, each deposited ​​by a specific method: hard ceramic biomaterials (TiO2 and YSZ - yttria stabilized zirconia) deposited by the method of deposition and plasma, respectively zirconium carbonitride (mono and multilayer) deposited by cathodic arc deposition method. The obtained coatings was analyzed using scanning electron microscopy coupled with EDS in order to characterize the morphology and composition of the coatings. The selected samples were tested for corrosion resistance. Corrosion resistance was determined by linear polarization technique, which involves plotting the potentiodynamic polarization curves of-1 V (vs. OC) to 1 V (vs SCE), with a scan rate of 0.5 mV / s. The corrosion tests was performed in physiological saline infusion (NaCl concentration 7%) at room temperature (25 ± 1 ° C) according to ASTM G15-97a. As a general conclusion we can say that layers ZrCN based presents the best parameter values ​​of corrosion and therefore the best corrosion resistance in the case of surgical instruments.

Publisher

Trans Tech Publications, Ltd.

Subject

Mechanical Engineering,Mechanics of Materials,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3