Accuracy of 320-detector row nonsubtracted and subtracted volume CT angiography in evaluating small cerebral aneurysms

Author:

Chen Wenhua1,Xing Wei2,He Zhongming1,Peng Ya3,Wang Caoye1,Wang Qi1

Affiliation:

1. Departments of Interventional Radiology,

2. Radiology, and

3. Neurosurgery, The Third Affiliated Hospital of Soochow University, Changzhou, People's Republic of China

Abstract

OBJECTIVEThe study aimed to assess the diagnostic accuracy of 320-detector row nonsubtracted and subtracted volume CT angiography (VCTA) in detecting small cerebral aneurysms (< 3 mm) compared with 3D digital subtraction angiography (3D DSA).METHODSSix hundred sixty-two patients underwent 320-detector row VCTA and 3D DSA for suspected cerebral aneurysms. Five neuroradiologists independently reviewed VCTA and 3D DSA images. The 3D DSA was considered the reference standard, and the sensitivity, specificity, and accuracy of nonsubtracted and subtracted VCTA in depicting small aneurysms were analyzed. A p value < 0.05 was considered a significant difference.RESULTSAccording to 3D DSA images, 98 small cerebral aneurysms were identified in 90 of 662 patients. Nonsubtracted VCTA depicted 90 small aneurysms. Ten small aneurysms were missed, and 2 small aneurysms were misdiagnosed. The missed small aneurysms were located almost in the internal carotid artery, near bone tissue. The sensitivity, specificity, and accuracy of nonsubtracted VCTA in depicting small aneurysms were 89.8%, 99.2%, and 96.5%, respectively, on a per-aneurysm basis. Subtracted VCTA depicted 97 small aneurysms. Three small aneurysms were missed, and 2 small aneurysms were misdiagnosed. The sensitivity, specificity, and accuracy of subtracted VCTA in depicting small aneurysms were 96.9%, 99.2%, and 98.6%, respectively, on a per-aneurysm basis. There was no difference in accuracy between subtracted VCTA and 3D DSA (p = 1.000). However, nonsubtracted VCTA had significantly less sensitivity than 3D DSA and subtracted VCTA (p = 0.039 and 0.016, respectively).CONCLUSIONSSubtracted 320-detector row VCTA is sensitive enough to replace 3D DSA in the diagnosis of small cerebral aneurysms (< 3 mm). The accuracy rate of nonsubtracted VCTA was lower than that of subtracted VCTA and 3D DSA, especially in the assessment of small internal carotid artery aneurysms adjacent to the skull base.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3