High frequency of low-virulent microorganisms detected by sonication of pedicle screws: a potential cause for implant failure

Author:

Prinz Vincent1,Bayerl Simon1,Renz Nora2,Trampuz Andrej2,Czabanka Marcus1,Woitzik Johannes1,Vajkoczy Peter1,Finger Tobias1

Affiliation:

1. Department of Neurosurgery and

2. Center for Musculoskeletal Surgery, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany

Abstract

OBJECTIVELoosening of pedicle screws is a frequent complication after spinal surgery. Implant colonization with low-virulent microorganisms forming biofilms may cause implant loosening. However, the clinical evidence of this mechanism is lacking. Here, the authors evaluated the potential role of microbial colonization using sonication in patients with clinical pedicle screw loosening but without signs of infection.METHODSAll consecutive patients undergoing hardware removal between January 2015 and December 2017, including patients with screw loosening but without clinical signs of infection, were evaluated. The removed hardware was investigated using sonication.RESULTSA total of 82 patients with a mean (± SD) patient age of 65 ± 13 years were eligible for evaluation. Of the 54 patients with screw loosening, 22 patients (40.7%) had a positive sonication result. None of the 28 patients without screw loosening who served as a control cohort showed a positive sonication result (p < 0.01). In total, 24 microorganisms were detected in those 22 patients. The most common isolated microorganisms were coagulase-negative staphylococci (62.5%) and Cutibacterium acnes (formerly known as Propionibacterium acnes) (25%). When comparing only the patients with screw loosening, the duration of the previous spine surgery was significantly longer in patients with a positive microbiological result (288 ± 147 minutes) than in those with a negative result (201 ± 103 minutes) (p = 0.02).CONCLUSIONSThe low-virulent microorganisms frequently detected on pedicle screws by using sonication may be an important cause of implant loosening and failure. Longer surgical duration increases the likelihood of implant colonization with subsequent screw loosening. Sonication is a highly sensitive approach to detect biofilm-producing bacteria, and it needs to be integrated into the clinical routine for optimized treatment strategies.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3