A radiographic computed tomography–based study to determine the ideal entry point, trajectory, and length for safe fixation using C-2 pars interarticularis screws

Author:

Hoh Daniel J.1,Liu Charles Y.1,Wang Michael Y.2

Affiliation:

1. 1Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, California; and

2. 2Department of Neurological Surgery, Miller School of Medicine, University of Miami, Florida

Abstract

Object Effective methods for fixation of the axis include C1–2 transarticular and C-2 pedicle screw placement. Both techniques pose a risk of vertebral artery (VA) injury in patients with narrow pedicles or an enlarged, high-riding VA. Pars screws at C-2 avoid the pedicle, but can cause VA injury with excessively long screws. Therefore, the authors evaluated various entry points and trajectories to determine ideal pars screw lengths that avoid breaching the transverse foramen. Methods Both pars were studied on 50 CT scans (100 total). Various pars lengths were assessed using 2 entry points and 3 trajectories (6 measurements). Entry point A was the superior one-fourth of the lateral mass. Entry point B was 3-mm rostral to the inferior aspect of the lateral mass. Using entry points A and B, Trajectory 1 was the minimum distance to the transverse foramen; Trajectory 2 was the maximum distance to the transverse foramen; and Trajectory 3 was the steepest angle to the pars/C-2 superior facet junction without transverse foramen breach. Results The mean patient age was 46 ± 17 years, and 84% of the CT scans reviewed were obtained in men. There was no significant difference in right or left measurements. Entry point B demonstrated greater pars lengths for each trajectory compared with entry point A (p < 0.0001). For both entry points, Trajectory 3 provided the greatest pars length. Using Trajectory 3 with entry point B, 84, 95, and 99% had a pars length that measured ≥ 18, 16, and 14 mm, respectively. Using Trajectory 3 with Entry point A, only 41, 64, and 87% had a pars length that measured ≥ 18, 16, and 14 mm, respectively. Conclusions Using an entry point 3-mm rostral to the inferior edge of the lateral mass and a trajectory directed toward the superior facet/pars junction, 99% of partes interarticularis in this study would tolerate a 14-mm screw without breach of the transverse foramen.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3