Continuous intracranial pressure monitoring via the shunt reservoir to assess suspected shunt malfunction in adults with hydrocephalus

Author:

Geocadin Romergryko G.12,Varelas Panayiotis N.3,Rigamonti Daniele24,Williams Michael A.124

Affiliation:

1. 1Departments of Neurology and

2. 2Neurosurgery, and

3. 4Department of Neurology, Henry Ford Hospital, Detroit, Michigan

4. 3Adult Hydrocephalus Program, Johns Hopkins Medical Institutions, Baltimore, Maryland; and

Abstract

Object The authors attempted to determine whether continuous intracrnial pressure monitoring via the shunt resevoir identifies ventriculoperitoneal (VP) shunt malfunctions that are not identified by radionuclide shunt patency study or shunt tap in adults with hydrocephalus. Methods During a 2-year period, 26 adults underwent 32 in-hospital continuous intracranial pressure (ICP) monitoring evaluations via needle access of a shunt reservoir. Monitoring was performed for 26.8 ± 13.8 hours (mean ± standard deviation). No ICP waveform abnormality was detected in 31% of the evaluations (10 of 32). In contrast, abnormalities were detected in 69% (22 of 32 evaluations), including B waves (nine of 22 evaluations), siphoning (nine of 22 evaluations), and variable ICP (two of 22 evaluations). In 20 (91%) of these 22 evaluations, the ICP abnormality was detected only after continuous ICP monitoring; in the other two evaluations, ICP became abnormal immediately on accessing the shunt reservoir. On the basis of the ICP monitoring results, shunt revision was performed in 66% (21 of 32 evaluations) and medical therapy was administered in 34% (11 of 32 evaluations). Shunt revision led to symptom improvement in 82% (18 of 22 patients) and no change in 18% (four of 22 patients); medical therapy led to improvement in 18% (two of 11 patients), worsening in 18% (two of 11 patients), and no change in 64% (seven of 11 patients; p < 0.05). Conclusions Continuous ICP monitoring via the shunt reservoir provides a more accurate assessment of shunt malfunction than transient ICP monitoring with a shunt tap or a radionuclide shunt patency study. It is a safe method for evaluating patients with suspected VP shunt malfunction, provides in vivo assessment of the effect of the shunt system on a patient's ICP, and can lead to more effective shunt revision.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Neurology (clinical),General Medicine,Surgery

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3