Dural sinus stent placement for idiopathic intracranial hypertension

Author:

Kumpe David A.12,Bennett Jeffrey L.34,Seinfeld Joshua12,Pelak Victoria S.34,Chawla Ashish1,Tierney Mary1

Affiliation:

1. Departments of Radiology,

2. Neurosurgery,

3. Neurology, and

4. Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora, Colorado

Abstract

Object The use of unilateral dural sinus stent placement in patients with idiopathic intracranial hypertension (IIH) has been described by multiple investigators. To date there is a paucity of information on the angiographic and hemodynamic outcome of these procedures. The object of this study was to define the clinical, angiographic, and hemodynamic outcome of placement of unilateral dural sinus stents to treat intracranial venous hypertension in a subgroup of patients meeting the diagnostic criteria for IIH. Methods Eighteen consecutive patients with a clinical diagnosis of IIH were treated with unilateral stent placement in the transverse-sigmoid junction region. All patients had papilledema. All 12 female patients had headaches; 1 of 6 males had headaches previously that disappeared after weight loss. Seventeen patients had elevated opening pressures at lumbar puncture. Twelve patients had opening pressures of 33–55 cm H2O. All patients underwent diagnostic cerebral arteriography that showed venous outflow compromise by filling defects in the transverse-sigmoid junction region. All patients underwent intracranial selective venous pressure measurements across the filling defects. Follow-up arteriography was performed in 16 patients and follow-up venography/venous pressure measurements were performed in 15 patients. Results Initial pressure gradients across the filling defects ranged from 10.5 to 39 mm Hg. Nineteen stent procedures were performed in 18 patients. One patient underwent repeat stent placement for hemodynamic failure. Pressure gradients were reduced in every instance and ranged from 0 to 7 mm Hg after stenting. Fifteen of 16 patients in whom ophthalmological follow-up was performed experienced disappearance of papilledema. Follow-up arteriography in 16 patients at 5–99 months (mean 25.3 months, median 18.5 months) showed patency of all stents without in-stent restenosis. Two patients had filling defects immediately above the stent. Four other patients developed transverse sinus narrowing above the stent without filling defects. One of these patients underwent repeat stent placement because of hemodynamic deterioration. Two of the other 3 patients had hemodynamic deterioration with recurrent pressure gradients of 10.5 and 18 mm Hg. Conclusions All stents remained patent without restenosis. Stent placement is durable and successfully eliminates papilledema in appropriately selected patients. Continuing hemodynamic success in this series was 80%, and was 87% with repeat stent placement in 1 patient.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3