Hemodynamic instability during carotid artery stenting: the relative contribution of stent deployment versus balloon dilation

Author:

Bussière Miguel12,Lownie Stephen P.12,Lee Donald1,Gulka Irene1,Leung Andrew1,Pelz David M.1

Affiliation:

1. Division of Neuroradiology, Department of Medical Imaging, and

2. Department of Clinical Neurological Sciences, London Health Sciences Centre, London, Ontario, Canada

Abstract

Object Hemodynamic instability may complicate carotid angioplasty and stenting in up to 40% of patients. The authors have previously demonstrated that primary self-expanding stent placement alone can gradually dilate severely stenosed carotid arteries without the use of balloons. The authors hypothesized that eliminating the balloon would reduce carotid baroreceptor stimulation, thereby decreasing the incidence of hemodynamic instability. Methods Ninety-seven high surgical risk patients with symptomatic, severely stenosed carotid arteries were treated with the intention of using a self-expanding stent alone. Seventy-seven arteries (79%) were treated with stenting alone, and 20 required angioplasty (21%). Results Intraprocedural bradycardia (heart rate < 60 bpm) developed in 29 patients (38%) and hypotension (systolic blood pressure < 90 mm Hg) occurred in 1 patient (1%) treated with stenting alone. Fourteen patients (70%) who underwent angioplasty and stenting had bradycardia, and hypotension developed in 4 (20%). Atropine, glycopyrrolate, or vasopressors were required in 8% of patients who received stenting alone, compared to 30% of patients who underwent angioplasty. In the first 24 hours after treatment, hypotension or bradycardia developed in 25 patients (32%) who had undergone stent placement alone, and in 15 patients (75%) after stent placement and balloon angioplasty. There was no difference in the occurrence of intra- or postprocedural hypertension (systolic blood pressure > 160 mm Hg) between patients treated with stenting alone or stenting and balloons. Factors independently associated with hemodynamic depression included baseline heart rate and balloon use. Conclusions Hemodynamic instability during and after carotid artery stenting was observed more frequently when balloon angioplasty was required than when stent placement was performed without concurrent balloon angioplasty.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3