Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation

Author:

Kim Terrence T.1,Drazin Doniel2,Shweikeh Faris2,Pashman Robert1,Johnson J. Patrick2

Affiliation:

1. 1Departments of Orthopaedics and

2. 2Neurosurgery, Cedars-Sinai Medical Center, Los Angeles, California

Abstract

Object Intraoperative CT image–guided navigation (IGN) has been increasingly incorporated into minimally invasive spine surgery (MIS). The vast improvement in image resolution and virtual real-time images with CT-IGN has proven superiority over traditional fluoroscopic techniques. The authors describe their perioperative MIS technique using the O-arm with navigation, and they report their postoperative experience, accuracy results, and technical aspects. Methods A retrospective review of 48 consecutive adult patients undergoing minimally invasive percutaneous posterior spinal fusion with intraoperative CT-IGN between July 2010 and August 2013 at Cedars-Sinai Medical Center was performed. Two surgeons assessed 290 screws in a blinded fashion on intraoperative O-arm images and postoperative CT scans for bony pedicle wall breach. Grade 1 breach was defined to be < 2 mm, Grade 2 breach to be between 2 and 4 mm, and a Grade 3 breach to be > 4 mm. Additionally, anterior vertebral body breach was recorded. Results Of 290 pedicle screws placed, 280 (96.6%) were in an acceptable position without cortical wall or anterior breach. Of the 10 breaches (3.4%) 5 were lateral (50%), 4 were medial, and 1 was anterior; 90% of breaches were Grade 1–2 and all medial breaches were Grade 1. The one Grade 3 breach was lateral. No vascular or neurological complications were observed intraoperatively, and no significant postoperative complications were noted. The mean clinical follow-up period was 18 months (range 3–39 months). The overall clinical outcomes, measured using the visual analog scale (back pain scores), were improved significantly postoperatively at 3 months compared with preoperatively (visual analog score 6.35 vs 3.57; p < 0.0001). No revision surgery was performed for screw misplacement or neurological deterioration. Conclusions New CT-IGN with the mobile O-arm scanner has increased the accuracy of pedicle screw/instrumentation placement using MIS techniques. The authors' high (96.6%) accuracy rate in MIS compares favorably with historical published accuracy rates for fluoroscopy-based techniques. Additional advantages of CT-IGN over fluoroscopic imaging methods are lower occupational radiation exposure for the surgical team, reduced need for postoperative imaging, and decreased rates of revision surgery. For now, the authors simply conclude that use of intraoperative CT-IGN is safe and accurate.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Neurology (clinical),General Medicine,Surgery

Cited by 76 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Complications of Minimally Invasive Spine Surgery;Contemporary Neurosurgery;2024-02

2. Image-Guided Spine Surgery;Neurosurgery Clinics of North America;2024-01

3. A spatial registration method based on 2D–3D registration for an augmented reality spinal surgery navigation system;The International Journal of Medical Robotics and Computer Assisted Surgery;2023-12-19

4. Lateral access minimally invasive spine surgery in adult spinal deformity;Journal of Orthopaedics;2023-11

5. Free-Hand MIS TLIF without 3D Navigation—How to Achieve Low Radiation Exposure for Both Surgeon and Patient;Journal of Clinical Medicine;2023-08-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3