Comparison of pulsed versus continuous convective flow for central nervous system tissue perfusion

Author:

Nduom Edjah K.12,Walbridge Stuart1,Lonser Russell R.1

Affiliation:

1. Surgical Neurology Branch, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland; and

2. Department of Neurological Surgery, Emory University, Atlanta, Georgia

Abstract

Object Although pulsatile and continuous infusion paradigms have been described for convective delivery of drugs, the effectiveness and properties of each flow paradigm are unknown. To determine the effectiveness and properties of pulsatile and continuous convective infusion paradigms, the authors compared these convective flow methods in the gray and white matter of primates. Methods Six primates (Macaca mulatta) underwent convective infusion of Gd-DPTA (5 mM) into the cerebral gray matter (thalamus) or white matter (frontal lobe) using pulsed (intermittent pulses of 15 μl/min) or continuous (1 μl/min) convective flow. Results were assessed by clinical MRI and histological analyses. Results Distribution of Gd-DTPA infusate in gray and white matter by pulsed and continuous flow was clearly identified using MRI, which revealed that both convective flow methods demonstrated an increase in the volume of distribution (Vd) with increasing volume of infusion (Vi) in the surrounding gray and white matter. Although the mean (± SD) gray matter Vd:Vi ratio for the pulsed infusions (4.2 ± 0.5) was significantly lower than the mean Vd:Vi ratio for continuous infusions (5.4 ± 0.5; a 22% difference [p = 0.0006]), the difference between pulsed (3.8 ± 0.4) and continuous (4.3 ± 1.2) infusions in white matter was not significantly different (p = 0.3). Pulsed infusions were associated with more leakback (12.3% ± 6.4% of Vi) than continuous infusions (3.9% ± 7.8%), although this difference was not significant (p = 0.2). All animals tolerated the infusions and there was no histological evidence of tissue injury at the infusion sites. Conclusions Although pulsed and continuous infusion flow paradigms can be safely and effectively used for convective delivery into both gray and white matter, continuous infusion is associated with a higher Vd:Vi ratio than pulsatile infusion in gray matter. High rates of infusion (15 μl/min) can be used to deliver infusate without any significant leakback and without any clinical or histological evidence of injury.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3