Author:
Heary Robert F.,Bono Christopher M.,Black Margaret
Abstract
Object. The authors evaluated the accuracy of placement of thoracic pedicle screws by performing postoperative computerized tomography (CT) scanning. A grading system is presented by which screw placement is classified in relation to neurological, bone, and intrathoracic landmarks.
Methods. One hundred eighty-five thoracic pedicle screws were implanted in 27 patients with the assistance of computer image guidance or fluoroscopy. Postoperative CT scanning was conducted to determine a grade for each screw: Grade I, entirely contained within pedicle; Grade II, violates lateral pedicle but screw tip entirely contained within the vertebral body (VB); Grade III, tip penetrates anterior or lateral VB; Grade IV, breaches medial or inferior pedicle; and Grade V, violates pedicle or VB and endangers spinal cord, nerve root, or great vessels and requires immediate revision. Based on anatomical morphometry, the spine was subdivided into upper (T1–2), middle (T3–6), and lower (T7–12) regions. Statistical analyses were performed to compare regions. The mean follow-up period was 37.6 months.
The following postoperative CT scanning—documented grades were determined: Grade I, 160 screws (86.5%); Grade II, 15 (8.1%); Grade III, six (3.2%); Grade IV, three (1.6%); and Grade V, one (0.5%). Among cases involving screw misplacements, Grade II placement was most common, and this occurred most frequently in the middle thoracic region.
Conclusions. The authors' grading system has advantages over those previously described; however, further study to determine its reliability, reproducibility, and predictive value of clinical sequelae is warranted. Postoperative CT scanning should be considered the gold standard for evaluating thoracic pedicle screw placement.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Cited by
79 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献