Occipitocervical reconstruction with the Ohio Medical Instruments Loop: results of a multicenter evaluation in 30 cases

Author:

Singh Sheila K.,Rickards Lynda,Apfelbaum Ronald I.,Hurlbert R. John,Maiman Dennis,Fehlings Michael G.

Abstract

Object. Stabilization of the craniocervical junction (CCJ) remains a significant challenge. In this multicenter study, the authors present the results of an evaluation of a precontoured titanium implant, the Ohio Medical Instruments (OMI) Loop, for craniocervical fixation. Methods. In this multicenter retrospective study the authors evaluated 30 patients (16 female, 14 male; mean age 53.8 years) with rheumatoid arthritis (15 cases), traumatic occipitoatlantoaxial instability (six cases), congenital vertebral anomalies (two cases), instability due to basilar invagination in the setting of Chiari malformation (two cases), or Down syndrome (one case), tumor (one case), os odontoideum (two cases), and pseudarthrosis/other (one case), who underwent OMI Loop—assisted occipitocervical reconstruction. The mean follow-up period was 25.4 months (range 6–60 months). A solid reconstruction was achieved in 29 of 30 cases; there was only one case of hardware failure requiring reoperation. Noncritical hardware failure occurred in two patients in whom partial occipital screw backout occurred but did not necessitate reoperation. There were no perioperative neurological complications. One patient (3.3%) experienced a delayed postoperative worsening of myelopathy at 1 year that resolved with further surgery. Postoperatively, in 66.6% of patients the degree of myelopathy remained stable (as measured by American Spinal Injury Association [ASIA] scores), whereas 30% improved by one or more ASIA grade. The rate of osseous fusion was 96.6% at a mean follow-up period of 25.4 months. Conclusions. The authors found that the OMI Loop is a versatile precontoured occipitocervical fixation device that can be applied to a wide range of CCJ lesions. It provides excellent immediate rigid fixation of the CCJ, a high rate of osseous fusion, and a low rate of hardware failure.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3