High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms

Author:

Xiang Jianping123,Damiano Robert J.13,Lin Ning24,Snyder Kenneth V.125,Siddiqui Adnan H.125,Levy Elad I.125,Meng Hui1236

Affiliation:

1. Toshiba Stroke and Vascular Research Center,

2. Department of Neurosurgery,

3. Department of Mechanical and Aerospace Engineering,

4. Department of Neurosurgery, Weill Cornell Medical Center and NewYork-Presbyterian Hospital, New York, New York

5. Department of Radiology, University at Buffalo, The State University of New York, Buffalo; and

6. Department of Biomedical Engineering, and

Abstract

OBJECT Flow diversion via Pipeline Embolization Device (PED) represents the most recent advancement in endovascular therapy of intracranial aneurysms. This exploratory study aims at a proof of concept for an advanced device-modeling tool in conjunction with computational fluid dynamics (CFD) to evaluate flow modification effects by PED in actual, treated cases. METHODS The authors performed computational modeling of 3 PED-treated complex aneurysm cases. The patient in Case 1 had a fusiform vertebral aneurysm treated with a single PED. In Case 2 the patient had a giant internal carotid artery (ICA) aneurysm treated with 2 PEDs. Case 3 consisted of tandem ICA aneurysms (III-a and III-b) treated by a single PED. The authors’ recently developed high-fidelity virtual stenting (HiFiVS) technique was used to recapitulate the clinical deployment process of PEDs in silico for these 3 cases. Pretreatment and posttreatment aneurysmal hemodynamics studies performed using CFD simulation were analyzed. Changes in aneurysmal flow velocity, inflow rate, wall shear stress (WSS), and turnover time were calculated and compared with the clinical outcome. RESULTS In Case 1 (occluded within the first 3 months), the aneurysm had the most drastic flow reduction after PED placement; the aneurysmal average velocity, inflow rate, and average WSS were decreased by 76.3%, 82.5%, and 74.0%, respectively, whereas the turnover time was increased to 572.1% of its pretreatment value. In Case 2 (occluded at 6 months), aneurysmal average velocity, inflow rate, and average WSS were decreased by 39.4%, 38.6%, and 59.1%, respectively, and turnover time increased to 163.0%. In Case 3, Aneurysm III-a (occluded at 6 months) had a decrease by 38.0%, 28.4%, and 50.9% in average velocity, inflow rate, and average WSS, respectively, and turnover time increased to 139.6%, which was quite similar to Aneurysm II. Surprisingly, the adjacent Aneurysm III-b had more substantial flow reduction (a decrease by 77.7%, 53.0%, and 84.4% in average velocity, inflow rate, and average WSS, respectively, and an increase to 213.0% in turnover time) than Aneurysm III-a, which qualitatively agreed with angiographic observation at 3-month follow-up. However, Aneurysm III-b remained patent at both 6 months and 9 months. A closer examination of the vascular anatomy in Case 3 revealed blood draining to the ophthalmic artery off Aneurysm III-b, which may have prevented its complete thrombosis. CONCLUSIONS This proof-of-concept study demonstrates that HiFiVS modeling of flow diverter deployment enables detailed characterization of hemodynamic alteration by PED placement. Posttreatment aneurysmal flow reduction may be correlated with aneurysm occlusion outcome. However, predicting aneurysm treatment outcome by flow diverters also requires consideration of other factors, including vascular anatomy.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3