Affiliation:
1. Klinik Healthcare Solutions Oy
2. University of Eastern Finland
3. Kuopio University Hospital
Abstract
Abstract
Background
Computerized clinical decision support systems (CDSSs) are increasingly adopted in health care to optimize resources and streamline patient flow. However, they often lack scientific validation against standard medical care.
Objective
The purpose of this study was to assess the performance, safety, and usability of a CDSS in a university hospital emergency department setting in Kuopio, Finland.
Methods
Patients entering the emergency department were asked to voluntarily participate in this study. Patients aged 17 years or younger, patients with cognitive impairments, and patients who entered the unit in an ambulance or with the need for immediate care were excluded. Patients completed the CDSS web-based form and usability questionnaire when waiting for the triage nurse’s evaluation. The CDSS data were anonymized and did not affect the patients’ usual evaluation or treatment. Retrospectively, 2 medical doctors evaluated the urgency of each patient’s condition by using the triage nurse’s information, and urgent and nonurgent groups were created. The International Statistical Classification of Diseases, Tenth Revision diagnoses were collected from the electronic health records. Usability was assessed by using a positive version of the System Usability Scale questionnaire.
Results
In total, our analyses included 248 patients. Regarding urgency, the mean sensitivities were 85% and 19%, respectively, for urgent and nonurgent cases when assessing the performance of CDSS evaluations in comparison to that of physicians. The mean sensitivities were 85% and 35%, respectively, when comparing the evaluations between the two physicians. Our CDSS did not miss any cases that were evaluated to be emergencies by physicians; thus, all emergency cases evaluated by physicians were evaluated as either urgent cases or emergency cases by the CDSS. In differential diagnosis, the CDSS had an exact match accuracy of 45.5% (97/213). The usability was good, with a mean System Usability Scale score of 78.2 (SD 16.8).
Conclusions
In a university hospital emergency department setting with a large real-world population, our CDSS was found to be equally as sensitive in urgent patient cases as physicians and was found to have an acceptable differential diagnosis accuracy, with good usability. These results suggest that this CDSS can be safely assessed further in a real-world setting. A CDSS could accelerate triage by providing patient-provided data in advance of patients’ initial consultations and categorize patient cases as urgent and nonurgent cases upon patients' arrival to the emergency department.
Subject
Health Information Management,Health Informatics