Accuracy-Based Vitamin D Survey: Six Years of Quality Improvement Guided by Proficiency Testing

Author:

Erdman Patrick1,Palmer-Toy Darryl E.1,Horowitz Gary1,Hoofnagle Andrew1

Affiliation:

1. From the Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, New York, New York (Dr Erdman); Regional Reference Labs, Southern California Permanente Medical Group, North Hollywood (Dr Palmer-Toy); the Department of Pathology and Laboratory Medicine, Tufts Medical Center, Boston, Massachusetts (Dr Horowitz); and the Department of Laboratory Medicine, University of Washington

Abstract

Context.— The goal of the College of American Pathologists Accuracy-Based Proficiency Testing Program is to promote the quality, standardization, and harmonization of clinical laboratory results through proficiency testing specimens that are free from matrix effects, have target values that are traceable to reference methods, and that probe the limitations of current methods. Objective.— To summarize the first 6 years of the Accuracy-Based Vitamin D Survey and highlight key insights from the data generated as it relates to assay performance. Design.— Accuracy-based challenges were created by using pooled human serum samples. Certain samples were derived from participants in an institutional review board–approved protocol in which vitamin D–deficient participants were treated with ergocalciferol (vitamin D2). Reference targets for the survey were set by the Centers for Disease Control and Prevention using isotope-dilution liquid chromatography–tandem mass spectrometry. Each method was compared with the reference method procedure over the course of the program (n = 43 proficiency testing samples). Results.— Linear regression versus the reference method procedure revealed proportional biases across the methods, ranging from 0.0% to 16.7%. Pearson correlation coefficients (r2) ranged from 0.902 to 0.996. Results were influenced by the concentration of 25-hydroxyvitamin D2 as well as the C-3 epimer of 25-hydroxyvitamin D3. During the 6 years, 2 manufacturers altered their assays to match the reference method procedure more closely. Conclusions.— There is considerable bias, both proportional bias and sample-specific matrix effects, affecting many assays. This ongoing accuracy-based proficiency testing program for vitamin D will provide the data needed for laboratories and manufacturers to improve their assays and thereby patient care.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3