Timeliness and Accuracy of Reporting Preliminary Blood Culture Results: A College of American Pathologists Q-Probes Study of 65 Institutions

Author:

Schifman Ron B.1,Meier Frederick A.1,Souers Rhona J.1

Affiliation:

1. From Diagnostics, Southern Arizona VA Healthcare System, University of Arizona College of Medicine, Tucson (Dr Schifman); the Department of Pathology, Massachusetts General Hospital, Boston (Dr Meier); and the Department of Biostatistics, College of American Pathologists, Northfield, Illinois (Ms Souers).

Abstract

Context The speed and accuracy of preliminary blood culture reports impacts patient management and outcomes. Objective To evaluate the accuracy and timeliness of preliminary blood culture results among multiple laboratories. Design Q-Probes participants collected turnaround time (TAT) data on preliminary Gram stains, compared accuracy of up to 100 preliminary to final culture Gram stain results, and described blood culture laboratory practices. Results Sixty-four laboratories and 5031 blood cultures were evaluated. All participants used continuously monitoring blood culture systems. Median TAT from initial growth detection to notification of results was 45 minutes, with the longest component being preparation of Gram stains (median time = 25 minutes). Participants (N = 40) reporting a continuous schedule for processing blood cultures had significantly lower overall TAT (medianm= 37 minutes) compared with 15 participants with intermittent processing schedules (medianm= 124 minutes),mPm= .003. Time to complete Gram stain processing was lower (median time = 21 minutes) for 39 participants using continuous processing schedule compared with 14 others (median timem= 67 minutes),mPm= .03. Goals for total TAT were used by 27 of 56 participants (48.2%). Having goals did not significantly affect TAT. A total of 4962 of 5021 Gram stain results (98.8%) agreed with final culture results. The highest discrepancy rates occurred among gram-positive bacilli (20 of 335; 6.0%) and mixed cultures (22 of 106; 20.8%). Conclusions This study provides benchmarks for assessing blood culture quality performance. Timeliness and accuracy of preliminary blood culture reports were excellent. However, nearly one-third of laboratories did not process blood cultures continuously. This significantly prolonged reporting results, which could affect patient outcomes.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3